Chrome Extension
WeChat Mini Program
Use on ChatGLM

The Association Between Cerebral Blood Flow Variations During On-Pump Coronary Artery Bypass Grafting Surgery and Postoperative Delirium.

Caterina Sampaolesi,Erika Casarotta, Giacomo Gresti, Giulia Mariotti, Leonardo Pisani, Diego Veccia,Marco Di Eusanio,Pietro Giorgio Malvindi,Abele Donati, Christopher Maria Munch

PERFUSION-UK(2024)

Azienda Osped Univ Marche | Anesthesia & Intens Care Unit | Cardiosurg Anesthesia & Intens Care Unit

Cited 0|Views8
Abstract
Introduction Postoperative delirium (POD) has a major impact on patient recovery after cardiac surgery. Although its pathophysiology remains unclear, there could be a correlation between cerebral blood flow (CBF) variations during cardio-pulmonary bypass (CPB) and POD. Our study aimed to evaluate whether variations in on-pump CBF, compared to pre-anesthesia and pre-CPB values, are associated with POD following coronary artery bypass grafting (CABG) surgery. Methods This prospective observational cohort study included 95 adult patients undergoing elective on-pump CABG surgery. Right middle cerebral artery blood flow velocity (MCAV) was assessed using Transcranial Doppler before anesthesia induction, before CPB and every fifteen minutes during CPB. Pre-anesthesia and pre-CPB values were chosen as baselines. Individual values, measured during CPB, were converted as percentage changes relative to these baselines and named as %MCAV0 and %MCAV1, respectively. POD was assessed using the Confusion Assessment Method for ICU (CAM-ICU) during the first 48 post-operative hours and with the 3-Minute Diagnostic Interview for Confusion Assessment Method (3D-CAM) on the fifth post-surgical day. Results Overall POD incidence was 17.9%. At 30 minutes of CPB, %MCAV0 was higher in POD group than in no-POD group ( p = .05). %MCAV0 at 45 minutes of CPB was significantly higher in POD group (87 (±17) %) than in no-POD group (68 (±24) %), p = .04. %MCAV1 at 30 and 45 minutes of CPB were higher in POD group than in no-POD group, at the limit of statistical significance. We found %MCAV1 > 100% in POD group, but not in no-POD group. Conclusions Significant differences in %MCAV0 became evident after 30 minutes of CPB, whereas differences in %MCAV1 at 45 minutes of CPB were at limit of statistical significance. In POD group %MCAV1 was higher than 100% at 30 and 45 minutes of CPB, which is supposed to be a sign of cerebral hyperperfusion. Monitoring CBF during CPB could have prognostic value for POD.
More
Translated text
Key words
postoperative delirium,transcranial Doppler,cerebral blood flow,coronary artery bypass grafting,perioperative cognitive disorders
求助PDF
上传PDF
Bibtex
AI Read Science
AI Summary
AI Summary is the key point extracted automatically understanding the full text of the paper, including the background, methods, results, conclusions, icons and other key content, so that you can get the outline of the paper at a glance.
Example
Background
Key content
Introduction
Methods
Results
Related work
Fund
Key content
  • Pretraining has recently greatly promoted the development of natural language processing (NLP)
  • We show that M6 outperforms the baselines in multimodal downstream tasks, and the large M6 with 10 parameters can reach a better performance
  • We propose a method called M6 that is able to process information of multiple modalities and perform both single-modal and cross-modal understanding and generation
  • The model is scaled to large model with 10 billion parameters with sophisticated deployment, and the 10 -parameter M6-large is the largest pretrained model in Chinese
  • Experimental results show that our proposed M6 outperforms the baseline in a number of downstream tasks concerning both single modality and multiple modalities We will continue the pretraining of extremely large models by increasing data to explore the limit of its performance
Upload PDF to Generate Summary
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Related Papers
Data Disclaimer
The page data are from open Internet sources, cooperative publishers and automatic analysis results through AI technology. We do not make any commitments and guarantees for the validity, accuracy, correctness, reliability, completeness and timeliness of the page data. If you have any questions, please contact us by email: report@aminer.cn
Chat Paper
GPU is busy, summary generation fails
Rerequest