谷歌浏览器插件
订阅小程序
在清言上使用

Fetal and Maternal Factors Predictive of Primary Cesarean Delivery at Term in a Low-Risk Population: NICHD Fetal Growth Studies—Singletons

AMERICAN JOURNAL OF PERINATOLOGY(2024)

引用 0|浏览0
暂无评分
摘要
Objective This study aimed to examine associations of fetal biometric and amniotic fluid measures with intrapartum primary cesarean delivery (PCD) and develop prediction models for PCD based on ultrasound parameters and maternal factors. Study Design Secondary analysis of the National Institute of the Eunice Kennedy Shriver National Institute of Child Health and Human Development (NICHD) Fetal Growth Studies-singleton cohort (2009-2013) including patients with uncomplicated pregnancies and intent to deliver vaginally at >= 37 (0/7) weeks. The estimated fetal weight, individual biometric parameters, fetal asymmetry measurements, and amniotic fluid single deepest vertical pocket assessed at the final scan (mean 37.5 +/- 1.9 weeks) were categorized as <10th, 10th to 90th (reference), and >90th percentiles. Logistic regression analyses examined the association between the ultrasound measures and PCD. Fetal and maternal SuperLearner prediction algorithms were constructed for the full and nulliparous cohorts. Results Of the 1,668 patients analyzed, 249 (14.9%) had PCD. The fetal head circumference, occipital-frontal diameter, and transverse abdominal diameter >90th percentile (adjusted odds ratio [aOR] = 2.50, 95% confidence interval [95% CI]: 1.39, 4.51; aOR = 1.86, 95% CI: 1.02, 3.40; and aOR = 2.13, 95% CI: 1.16, 3.89, respectively) were associated with PCD. The fetal model demonstrated poor ability to predict PCD in the full cohort and in nulliparous patients (area under the receiver-operating characteristic curve [AUC] = 0.56, 95% CI: 0.52, 0.61; and AUC = 0.54, 95% CI: 0.49, 0.60, respectively). Conversely, the maternal model had better predictive capability overall (AUC = 0.79, 95% CI: 0.75, 0.82) and in the nulliparous subgroup (AUC = 0.72, 95% CI: 0.67, 0.77). Models combining maternal/fetal factors performed similarly to the maternal model (AUC = 0.78, 95% CI: 0.75, 0.82 in full cohort, and AUC = 0.71, 95% CI: 0.66, 0.76 in nulliparas). Conclusion Although a few fetal biometric parameters were associated with PCD, the fetal prediction model had low performance. In contrast, the maternal model had a fair-to-good ability to predict PCD. Key Points Fetal HC >90th percentile was associated with cesarean delivery. Fetal parameters did not effectively predict PCD. Maternal factors were more predictive of PCD. Maternal/fetal and maternal models performed similarly. Prediction models had lower performance in nulliparas. d lower performance in nulliparas.
更多
查看译文
关键词
estimated fetal weight,fetal biometric parameters,maternal factors,primary cesarean delivery,prediction models
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要