Urogenital schistosomiasis is caused by the parasitic trematode Schistosoma haematobium. Sensitive and specific point-of-care diagnostics are needed for elimination of this disease. Recombinase polymerase amplification (RPA) assays meet these criteria, and an assay to diagnose S. haematobium has been developed (Sh-RPA). However, false-positive results can occur, and optimisation of reaction conditions to mitigate these is needed. Ease of use and compatibility of DNA extraction methods must also be considered. Using synthetic DNA, S. haematobium genomic DNA (gDNA), and urine samples from clinical cases, Sh-RPA reactions incorporating different betaine concentrations (0 M, 1 M, 2.5 M, 12.5 M) and the sample-to-water ratios were tested to determine effects on assay specificity and sensitivity. In addition, five commercial DNA extraction kits suitable for use in resource-limited settings were used to obtain gDNA from single S. haematobium eggs and evaluated in terms of DNA quality, quantity, and compatibility with the Sh-RPA assay. All samples were also evaluated by quantitative polymerase chain reaction (qPCR) to confirm DNA acquisition. The analytical sensitivity of the Sh-RPA with all betaine concentrations was ≥ 10 copies of the synthetic Dra1 standard and 0.1 pg of S. haematobium gDNA. The addition of betaine improved Sh-RPA assay specificity in all reaction conditions, and the addition of 2.5 M of betaine together with the maximal possible sample volume of 12.7 µl proved to be the optimum reaction conditions. DNA was successfully isolated from a single S. haematobium egg using all five commercial DNA extraction kits, but the Sh-RPA performance of these kits varied, with one proving to be incompatible with RPA reactions. The addition of 2.5 M of betaine to Sh-RPA reactions improved reaction specificity whilst having no detrimental effect on sensitivity. This increases the robustness of the assay, advancing the feasibility of using the Sh-RPA assay in resource-limited settings. The testing of commercial extraction kits proved that crude, rapid, and simple methods are sufficient for obtaining DNA from single S. haematobium eggs, and that these extracts can be used with Sh-RPA in most cases. However, the observed incompatibility of specific kits with Sh-RPA highlights the need for each stage of a molecular diagnostic platform to be robustly tested prior to implementation.
更多
查看译文
关键词
Diagnostic,Molecular,Isothermal,Point-of-care,Schistosomiasis,Schistosoma haematobium,Urogenital schistosomiasis,Recombinase polymerase amplification
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要