谷歌浏览器插件
订阅小程序
在清言上使用

Corrosion Performance of 6061 Aluminium Alloy Protected by Plasma Electrolytic Oxidation Coatings Modified by Acrylic Acid

Aleksander Olesinski, Aleksandra Bugla,Dorota Babilas,Agnieszka Stolarczyk,Wojciech Simka,Maciej Sowa

CORROSION SCIENCE(2024)

引用 0|浏览0
暂无评分
摘要
Long-term corrosion studies (six weeks) of aluminium alloy 6061 treated by plasma electrolytic oxidation (PEO) with or without the addition of a corrosion inhibitor (acrylic acid) in oxygenated 3.5 wt% NaCl are reported. A two-step sequential procedure (PEO + enrichment with acrylic acid) was compared with PEO carried out in the presence of the inhibitor. EIS backed by ICP-OES and SEM data showed that the sequential method offers the best long-term protection. A new approach for testing weight loss due to corrosion underneath the PEO coatings is proposed. The obtained results are consistent with other methods used in the study.
更多
查看译文
关键词
A . Aluminium alloy,B . EIS,B . SEM,B . ICP-OES,C . Anodic films