First-in-human Use of a New Robotic Electromagnetic Navigation Bronchoscopic Platform with Integrated Tool-in-Lesion Tomosynthesis (tilt) Technology for Peripheral Pulmonary Lesions: the FRONTIER Study

Tajalli Saghaie,Jonathan P. Williamson,Martin Phillips, Dona Kafili, Sarika Sundar, D. Kyle Hogarth,Alvin Ing

Respirology(2024)

引用 0|浏览1
暂无评分
摘要
Background and Objective: As the presentation of pulmonary nodules increases, the importance of a safe and accurate method of sampling peripheral pulmonary nodules is highlighted. First-generation robotic bronchoscopy has successfully assisted navigation and improved peripheral reach during bronchoscopy. Integrating tool-in-lesion tomosynthesis (TiLT) may further improve yield. Methods: We performed a first-in-human clinical trial of a new robotic electromagnetic navigation bronchoscopy system with integrated digital tomosynthesis technology (Galaxy System, Noah Medical). Patients with moderate-risk peripheral pulmonary nodules were enrolled in the study. Robotic bronchoscopy was performed using electromagnetic navigation with TiLT-assisted lesion guidance. Non-specific results were followed up until either a clear diagnosis was achieved or repeat radiology at 6 months demonstrated stability. Results: Eighteen patients (19 nodules) were enrolled. The average lesion size was 20 mm, and the average distance from the pleura was 11.6 mm. The target was successfully reached in 100% of nodules, and the biopsy tool was visualized inside the target lesion in all cases. A confirmed specific diagnosis was achieved in 17 nodules, 13 of which were malignant. In one patient, radiological monitoring confirmed a true non-malignant result. This translates to a yield of 89.5% (strict) to 94.7% (intermediate). Complications included one pneumothorax requiring observation only and another requiring an overnight chest drain. There was one case of severe pneumonia following the procedure. Conclusion: In this first-in-human study, second-generation robotic bronchoscopy using electromagnetic navigation combined with integrated digital tomosynthesis was feasible with an acceptable safety profile and demonstrated a high diagnostic yield for small peripheral lung nodules. image ConclusionIn this first-in-human study, second-generation robotic bronchoscopy using electromagnetic navigation combined with integrated digital tomosynthesis was feasible with an acceptable safety profile and demonstrated a high diagnostic yield for small peripheral lung nodules. image
更多
查看译文
关键词
digital tomosynthesis,ii-RAB,image-integrated robotic assisted bronchoscopy,lung nodule,navigation bronchoscopy,peripheral pulmonary nodule,robotic bronchoscopy,solitary pulmonary nodule
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要