谷歌浏览器插件
订阅小程序
在清言上使用

Structural and electro-anatomical characterization of the equine pulmonary veins: implications for atrial fibrillation

S. T. Kjeldsen,S. D. Nissen,A. Saljic, E. M. Hesselkilde,H. Carstensen,S. M. Sattler,T. Jespersen,D. Linz, C. Hopster-Iversen,R. Kutieleh, P. Sanders,R. Buhl

JOURNAL OF VETERINARY CARDIOLOGY(2024)

引用 0|浏览1
暂无评分
摘要
Introduction/objectives: Spontaneous pulmonary vein (PV) activity triggers atrial fibrillation (AF) in humans. Although AF frequently occurs in horses, the origin remains unknown. This study investigated the structural and electro-anatomical properties of equine PVs to determine the potential presence of an arrhythmogenic substrate. Animals, materials and methods: Endocardial three-dimensional electro-anatomical mapping (EnSite Precision) using high-density (HD) catheters was performed in 13 sedated horses in sinus rhythm. Left atrium (LA) access was obtained retrogradely through the carotid artery. Post-mortem, tissue was harvested from the LA, right atrium (RA), and PVs for histological characterization and quantification of ion channel expression using immunohistochemical analysis. Results: Geometry, activation maps, and voltage maps of the PVs were created and a median of four ostia were identified. Areas of reduced conduction were found at the veno-atrial junction. The mean myocardial sleeve length varied from 28 +/- 13 to 49 +/- 22 mm. The PV voltage was 1.2 +/- 1.4 mV and lower than the LA (3.4 +/- 0.9 mV, P < 0.001). The fibrosis percentage was higher in PV myocardium (26.1 +/- 6.6 %) than LA (14.5 +/- 5.0 %, P = 0.003). L-type calcium channel (CaV1.2) expression was higher in PVs than LA (P = 0.001). T-type calcium channels (CaV3.3), connexin-43, ryanodine receptor-2, and small conductance calcium-activated potassium channel-3 was expressed in PVs. Conclusions: The veno-atrial junction had lower voltages, increased structural heterogeneity and areas of slower conduction. Myocardial sleeves had variable lengths, and a different ion channel expression compared to the atria. Heterogeneous properties of the PVs interacting with the adjacent LA likely provide the milieu for re-entry and AF initiation. (c) 2024 The Author(s). Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
更多
查看译文
关键词
Paroxysmal atrial fibrillation,Horse,Animal model,Electro-anatomical mapping,Immunohistochemistry
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要