Application of an absolute reference frame for methane clumped-isotope analyses

CHEMICAL GEOLOGY(2024)

引用 0|浏览4
暂无评分
摘要
Clumped-isotope analysis provides new constraints on the formation and evolution of methane. High-resolution isotope-ratio mass spectrometry (HR-IRMS) is a sensitive, precise, and stable analytical technique increasingly used in methane clumped-isotope analysis. However, the lack of standard reference frames hinders the comparison of data from different laboratories and the evaluation of accuracy. In this study, an absolute reference frame was introduced for HR-IRMS analysis of the multiply substituted methane isotopologues (CH3D)-C-13 and (CH2D2)-C-12. We evaluated the optimized performance of a Panorama (Nu Instruments, UK) HR-IRMS system by repeated analysis of an intra-laboratory standard gas, finding that these rare isotopologues can be analyzed separately with high precision, repeatability, and reproducibility. Internal precision (a key parameter in instrument performance) reached 0.15 parts per thousand - 0.25 parts per thousand for Delta(CH3D)-C-13 and 0.70 parts per thousand - 0.85 parts per thousand for Delta(CH2D2)-C-12 values, ensuring the reliability of data. Comparison of results before and after purification demonstrated that purification procedures caused negligible isotopic fractionation of clumped isotopes. Isotopic-exchange experiments revealed source effects in the MS ion source, depending on the difference in bulk H isotopic composition between sample and reference gas, but independent of bulk C isotopic composition. To improve analytical accuracy for methane isotopologues, an absolute reference frame was developed through experiments involving a suite of mixed gases of different H isotopic composition equilibrated at 100 degrees C and a standard gas equilibrated at 2 degrees C-500 degrees C. Based on the reference frame, raw data were processed with a non-linearity correction and converted to real values with empirical transformation functions. The reference frame was applied to analyses of two methane standard gases and three natural gases from Tarim Basin, China. Measured Delta(CH3D)-C-13 and Delta(CH2D2)-C-12 values for two standard gases were consistent with published values. Clumped-isotope signatures of natural gases preserve information related to the formation temperature of methane.
更多
查看译文
关键词
Methane,Clumped isotopes,High-resolution gas-source isotope-ratio mass,spectrometry,Absolute reference frame,Formation temperature
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要