Chrome Extension
WeChat Mini Program
Use on ChatGLM

Pre-oxygenation Using High-Flow Nasal Oxygen Versus Tight Facemask in Trauma Patients Undergoing Emergency Anaesthesia

Albin Sjoblom,Magnus Hedberg, Anders Gille, Andres Guerra, Vilde Aanesen,Ida-Maria Forsberg,Malin Jonsson Fagerlund

ACTA ANAESTHESIOLOGICA SCANDINAVICA(2024)

Cited 0|Views5
No score
Abstract
Background: Patients suffering from major traumatic injuries frequently require emergency anaesthesia. Due to often compromised physiology and the time-sensitive management, trauma patients may be more prone to desaturate during induction of anaesthesia. We hypothesised that pre-oxygenation using high-flow nasal oxygen would decrease the risk of desaturation during induction of anaesthesia in trauma patients and the study therefore aimed to compare the frequency of desaturation when pre-oxygenation was performed with high-flow nasal oxygen or a traditional facemask.Methods: This exploratory, prospective, before-and-after study was conducted at the Karolinska University Hospital, Sweden. Adult (>= 18 years of age) patients suffering major traumatic injuries needing emergency anaesthesia were included around the clock. Patients were pre-oxygenated using a tight-fitting facemask during the first nine months of enrollment. High-flow nasal oxygen was then introduced as a method for pre-oxygenation of trauma patients. The primary outcome was the proportion of patients desaturating <93% during induction of anaesthesia, assessed from the start of pre-oxygenation until one minute after intubation. Secondary outcomes included perceived difficulty of pre-oxygenation among anaesthetists (assessed on a scale between 1 and 10) and safety outcomes, such as incidence of regurgitations and intracranial gas (assessed radiologically).Results: Data from 96 patients were analysed. Facemask pre-oxygenation was performed in 66 patients, while 30 patients were pre-oxygenated with high-flow nasal oxygen. The most frequent trauma mechanisms were stabbing injuries (n = 34 (35%)) and fall injuries (n = 21 (22%)). There were no differences in patient characteristics between the groups. Eight (12%) versus three (10%) patients desaturated <93% in the facemask and high-flow nasal oxygen group respectively, OR 0.81 (95% CI 0.20-3.28), p = .76. Anaesthetists assessed pre-oxygenation using high-flow nasal oxygen as easier compared to facemask pre-oxygenation. No patient in any group showed signs of regurgitation. Among patients with facial or skull fractures requiring anaesthesia before radiology was performed, intracranial gas was seen in four (40%) patients pre-oxygenated with a facemask and in no patient pre-oxygenated with HFNO (p = .23).Conclusion: In this prospective study investigating trauma patients undergoing emergency anaesthesia, we could not see any difference in the number of patients desaturating when pre-oxygenation was performed with high-flow nasal oxygen compared to a tight-fitting facemask. Pre-oxygenation using high-flow nasal oxygen was assessed as easier compared to facemask pre-oxygenation.
More
Translated text
Key words
airway management,emergency anaesthesia,high-flow nasal oxygen,pre-oxygenation,rapid sequence induction,respiratory physiology,trauma
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined