谷歌浏览器插件
订阅小程序
在清言上使用

Evaluation of Therapeutic Capability of Emustil Drops against Tear Film Complications under Dry Environmental Conditions in Healthy Individuals

Medicina (Kaunas, Lithuania)(2023)

引用 1|浏览10
暂无评分
摘要
Background and Objectives: Dry eye disease (DED) is a multifactorial ailment of the tears and ocular surface. The purpose of this study was to assess the tear film physiology under controlled dry environmental conditions and compare the efficacy of oil-in-water emulsion drops on tear film parameters in protection and relief treatment modalities under low-humidity conditions. Emustil eye drops were used after exposure to a low-humidity environment in the relief method, whereas, in the protection method, the drops were applied before exposure to low humidity. Materials and Methods: 12 normal male subjects (mean age 34.0 & PLUSMN; 7.0 years) were exposed to ultra-dry environmental conditions. A number of tear film measurements were carried out under desiccating environmental conditions in a controlled environment chamber (CEC), where the chamber temperature sat at 21 & DEG;C with a relative humidity (RH) of 5%. Keeler's TearScope Plus and an HIRCAL grid were used to assess the tear break-up time and lipid layer thickness (LLT), and the evaporation rate was evaluated using a Servomed EP3 Evaporimeter. Results: LLT measurements showed that the dry environment affected LLT significantly (p = 0.031). The median grade of LLT dropped from grade 3 (50-70 nm) at 40% RH to grade 2 (13-50 nm) at 5% RH. A significant increase in LLT was seen after both modes of treatment, with a median LLT grade of 3 when the Emustil was used for both protection (p = 0.004) and relief (p = 0.016). The mean tear evaporation rate in normal environmental conditions (40%) was 40.46 & PLUSMN; 11.80 g/m2/h (0.11 & mu;L/min) and increased sharply to 83.77 & PLUSMN; 20.37 g/m2/h (0.25 & mu;L/min) after exposure to the dry environment. A minimal decrease in tear film evaporation rate was seen in relief; however, statistical tests showed that the decrease in tear film evaporation rate was not significant. Mean NITBUT dropped from 13.6 s at 40% RH to 6.6 s at 5% RH (p = 0.002). All NITBUT measurements at 5% RH (with or without the instillation of Emustil) were significantly lower than those at 40%. The instillation of Emustil at 5% RH resulted in a significant improvement in NITBUT for protection (p = 0.016) but this was not the case for relief (p = 0.0.56). Conclusions: A control environmental chamber (CEC) enables the analysis of tear film parameters comparable to those found in dry eye patients. This enables us to examine the capability of oil in emulsion drops to manage tear film disruption in healthy individuals. This study suggests that using Emustil oil-in-water emulsion before exposure to a dry environment should be advocated for people who work in dry environments.
更多
查看译文
关键词
dry eye disease (DED),tear evaporation rate,Emustil,controlled environment chamber,TearScope Plus,environmental stress
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要