谷歌浏览器插件
订阅小程序
在清言上使用

A Transient-Modeling-Based Grey-Box Method for Online Monitoring of DC-Link Capacitors

IEEE transactions on power electronics(2023)

引用 0|浏览12
暂无评分
摘要
This article proposes a suitable grey-box method for online monitoring of dc-link capacitors. It is found that the transient behavior of dc-link voltage in ac/dc and dc/dc converters is similar to the zero-state response of a parallel resistor-inductor-capacitor ( RLC ) circuit. Moreover, the damping factor α (related to capacitance) of the large-signal transient trajectories of converters can be chosen as a new health indicator of capacitors. Based on this, a nonintrusive transient equivalent circuit model based grey-box method is presented, which can realize the condition monitoring of dc-link capacitors with minimum dependency on the detailed topology and control information. Besides, it has features of relatively high applicability and extreme low sampling frequency requirement. Taking an ac/dc system and a dc/dc system as case studies, simulation results demonstrate the proposed method is suitable for converters with different load types. Moreover, a commercial power supply is chosen as an experimental case. Experimental results illustrate that the estimation errors of the damping factor α and dc-link capacitance are less than 1%. Furthermore, two typical application cases for a white-box system and a grey-box system are given to further illustrate the implementation of the proposed method.
更多
查看译文
关键词
Condition monitoring (CM),dc-link capacitor,grey-box method,transient modeling
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要