Chrome Extension
WeChat Mini Program
Use on ChatGLM

Utility of Human Epididymis Protein 4 in the Differential Diagnosis of Ascites.

Silvia Bergamo,Jaume Trape,Laura Gonzalez-Garcia,Carolina Gonzalez-Fernandez, Carme Vergara, Noelia de-la-Torre,Gloria Trujillo, Dolors Estivill, Marco Antonio Alvarez-Gonzalez, Laia Bosch,Marta Otero-Vinas, Carmen Bergos,Silvia Catot,Domingo Ruiz-Hidalgo,Sandra Ros,Francesc Sant

Clinical Biochemistry(2023)

Cited 0|Views13
No score
Abstract
Background and aims: Human epididymal protein 4 (HE4) may be a useful tool in the differential diagnosis of malignant ascites. The aim of this study was to evaluate the diagnostic utility of HE4 for detecting malignant ascites, taking into account the possible false positives identified with adenosine deaminase (ADA), C-reactive protein (CRP), % polynuclear cells (%PMN) and glomerular filtration rate (eGFR).Methods: Concentrations of HE4, ADA, %PMN and CRP were determined in 114 samples of peritoneal fluid and creatinine in serum in order to calculate eGFR.Results: Concentrations of HE4 presented significant differences (P = 0.028) in benign [median (interquartile range)] [582(372)] pmol/L) and malignant ascites ([8241(367)] pmol/L. Sensitivity was 21.2% and specificity 100%. Significant differences were also observed for HE4 between tumors of gynecological origin ([3165(8769)] pmol/L) and others ([665(663)] pmol/L), with a sensitivity of 67% and a specificity of 100%. Classifying according to possible false positives (ADA > 45U/L, CRP > 50 mg/L, %PMN > 90 and eGFR < 30 mL/ min/1.73 m(2)) at maximum specificity, a sensitivity of 33.3% was obtained for HE4, with a cut-off point of 2660 pmol/L. Without possible false positives (ADA < 45U/L, CRP < 50 mg/L, %PMN < 90 and eGFR >= 30 mL/min/ 1.73 m(2)), a sensitivity of 37.7% was obtained at 100% specificity for a cut-off point of 1041 pmol/L. Applying these criteria to the entire group, a sensitivity of 36.4% was obtained at maximum specificity.Conclusions: HE4 allows the identification of malignant ascites with moderate sensitivity at maximum specificity. HE4 levels can differentiate between tumors of gynecological origin and others. Classification according to possible false positives increases sensitivity without losing specificity.
More
Translated text
Key words
Malignant ascites,HE4,Differential diagnostic,False positives,ADA,CRP
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined