Enhanced Thromboresistance and Endothelialization of a Novel Fluoropolymer-Coated Left Atrial Appendage Closure Device.

JACC Clinical electrophysiology(2023)

引用 0|浏览56
暂无评分
摘要
BACKGROUND Device-related thrombus (DRT) after left atrial appendage closure (LAAC) procedures is a rare but potentially serious event. Thrombogenicity and delayed endothelialization play a role in the development of DRT. Fluorinated polymers are known to have thromboresistant properties that may favorably modulate the healing response to an LAAC device. OBJECTIVES The goal of this study was to compare the thrombogenicity and endothelial coverage (EC) after LAAC between the conventional uncoated WATCHMAN FLX (WM) and a novel fluoropolymer-coated WATCHMAN FLX (FP-WM). METHODS Canines were randomized for implantation with WM or FP-WM devices and given no postimplant antithrombotic/antiplatelet agents. The presence of DRT was monitored by using transesophageal echocardiography and verified histologically. The biochemical mechanisms associated with coating were assessed by using flow loop experiments to quantify albumin adsorption, platelet adhesion, and porcine implants to quantify EC and the expression of markers of endothelial maturation (ie, vascular endothelial-cadherin/p120-catenin). RESULTS Canines implanted with FP-WM exhibited significantly less DRT at 45 days than those implanted with WM (0% vs 50%; P < 0.05). In vitro experiments showed significantly greater albumin adsorption (52.8 [IQR: 41.0-58.3] mm(2) vs 20.6 [IQR: 17.2-26.6] mm(2); P 1/4 0.03) and significantly less platelet adhesion (44.7% [IQR: 27.2%-60.2%] vs 60.9% [IQR: 39.9%-70.1%]; P < 0.01) on FP-WM. Porcine implants showed significantly greater EC by scanning electron microscopy (87.7% [IQR: 83.4%-92.3%] vs 68.2% [IQR: 47.6%-72.8%]; P 1/4 0.03), and higher vascular endothelialcadherin/p120-catenin expression after 3 months on FP-WM compared with WM. CONCLUSIONS The FP-WM device showed significantly less thrombus and reduced inflammation in a challenging canine model. Mechanistic studies indicated that the fluoropolymer-coated device binds more albumin, leading to reduced platelet binding, less inflammation, and greater EC. (J Am Coll Cardiol EP 2023;9:1555-1567) (c) 2023 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要