谷歌浏览器插件
订阅小程序
在清言上使用

Use of Automated Capillary Immunoassays for Quantification of Antibodies in Chicken Sera Against Recombinant Salmonella Enterica Serotype Heidelberg Proteins.

Hung-Yueh Yeh,Jonathan G. Frye, Charlene R. Jackson, Quentin D. Read, John E. Line,Arthur Hinton Jr

Journal of microbiological methods(2023)

引用 0|浏览1
暂无评分
摘要
The classic immunoblot technique is an important tool for identification and characterization of target proteins. However, a standard protocol for this classic immunoblot assay involves many steps that may cause experimental variations in each step and make quantification of antibodies in sera difficult. A capillary electrophoresis-based immunoblot system was developed to reduce potential problems in variations during the experimental process, enable protein identification in an automatic manner and quantitate various isotypes of antibodies in sera. In the present study, we used this system to examine the purity of the recombinant proteins and measure amounts of various isotypes of immunoglobins in chicken sera after immunization with two recombinant Salmonella FliD and FimA proteins. A single band of each protein was detected in the gel like images by this system after purification by nickel-chelated affinity chromatography. A good linear range of the protein concentrations was also obtained for each recombinant protein. This automated capillary immunoblot system was successfully used for detection and quantification of various immunoglobin isotypes against two recombinant Salmonella proteins from the immunized chicken sera, but not the un-immunized chicken sera. The chicken immunoglobin G (IgG) antibody response to the FliD protein from the immunized group was 1110- and 51,400-fold higher than that from the un-immunized chickens both two- and three-weeks post-vaccination, respectively. It was also observed that IgM antibody against the FliD protein from the immunized chickens was 1030-fold higher than that from the un-immunized chickens two weeks post-vaccination, but the IgM response declined to 120-fold between two groups from two weeks to three weeks after immunization. The IgM antibody response to the FimA protein from the immunized group was 1.84- and 1.12-fold higher than that from the un-immunized group, respectively, both two- and three-weeks post-vaccination, while the IgG antibody response from the immunized group was 8.07- and 27.6-fold higher than that from the un-immunized group, respectively, during the same period. These results suggest that this capillary-based immunoblot assay can be an alternative method for analyses and quantitation of chicken humoral immune response before and after immunization with any antigens and/or for investigation in Salmonella outbreaks.
更多
查看译文
关键词
Salmonella enterica serotype Heidelberg,Capillary immunoassay,Chicken immunoglobulins,Salmonella proteins
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要