A pilot, prospective trial of IntuBrite® versus Macintosh direct laryngoscopy for paramedic endotracheal intubation in out of hospital cardiac arrest

BMC emergency medicine(2023)

引用 0|浏览0
暂无评分
摘要
Background Intubation in the case of out-of-hospital cardiac arrest (OHCA) is one of the most difficult procedures for Emergency Medical Services (EMS). The use of a laryngoscope with a dual light source is an interesting alternative to classic laryngoscopes. However, there are as yet no prospective data concerning the use of double light direct laryngoscopy (DL) by paramedics in traditional ground ambulance agencies in OHCA. Methods We performed a non-blinded trial in a single EMS in Poland within ambulances crews, comparing time and first pass success (FPS) for endotracheal intubation (ETI) in DL using the IntuBrite® (INT) and Macintosh laryngoscope (MCL) during cardiopulmonary resuscitation (CPR). We collected both patient and provider demographic information along with intubation details. The time and success rates were compared using an intention-to-treat analysis. Results Over a period of 40 months, a total of 86 intubations were performed using 42 INT and 44 MCL based on an intention-to-treat analysis. The FPS time of the ETI attempt (13.49 vs. 15.55 s) using an INT which was shorter than MCL was used ( p < 0.05). First attempt success (34/42, 80.9% vs. 29/44, 64.4%) was comparable for INT and MCL with no statistical significance. Conclusions We found a statistically significant difference in intubation attempt time when the INT laryngoscope was used. Intubation first attempt success rates with INT and MCL were comparable with no statistical significance during CPR performed by paramedics. Trial Registration Trial was registered in Clinical Trials: NCT05607836 (10/28/2022)
更多
查看译文
关键词
paramedic endotracheal intubation,direct laryngoscopy,cardiac arrest
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要