谷歌浏览器插件
订阅小程序
在清言上使用

Are Immediate Postoperative X-Rays Valuable in Evaluating Complications of Primary Total Hip Arthroplasty?

Arthroplasty(2022)

引用 0|浏览11
暂无评分
摘要
Purpose This study aimed to investigate the complications of primary total hip arthroplasty based on immediate postoperative X-rays. The overall quality and cost of X-rays were assessed. Methods The institutional database was queried to identify all patients who underwent total hip arthroplasty in a single institution between January 1, 2018, and December 31, 2018. Immediate postoperative X-rays were reviewed to identify the complications such as periprosthetic fractures, dislocation, and fixation failure. The quality and cost of X-ray were assessed. The complications were categorized as "known" and "unknown" according to the intraoperative fluoroscopic results. Results A total of 518 total hip arthroplasties were included in this study. Based on intraoperative fluoroscopy, periprosthetic fractures were found in 10 (2%) THAs. Compared to the X-rays taken immediately after surgery, 9 periprosthetic fractures (recorded as "known") were found and 1 was not (recorded as "unknown"). There was no significant difference between intraoperative fluoroscopy and X-rays (P > 0.05). Of the 518 X-rays, 225 (43%) were of suboptimal quality. The cost of a single portable pelvic X-ray was $647. Conclusion In total hip arthroplasty, X-rays taken immediately after surgery rarely reveal unknown complications. The X-rays are often of suboptimal quality, have minimal clinical utility, and are less cost-effective.
更多
查看译文
关键词
Total hip arthroplasty (THA),Complications,Radiographs,Value,Safety
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper