Cardiac magnetic resonance feature-tracking analysis of left atrial volumes and function in standard vs left-atrial focused images

European Heart Journal(2022)

引用 0|浏览24
暂无评分
摘要
Abstract Background Left atrial (LA) volume and function have shown prognostic value in several cardiac conditions. Routine cardiac magnetic resonance (CMR) evaluation of the LA is obtained from standard 2- and 4-chamber long-axis cine images focused on the left ventricle. Previous echocardiographic data showed that LA-focused apical views provide a more accurate estimation of LA maximum volume, as compared to standard apical images. CMR LA-focused imaging could improve the accuracy of LA morpho-functional analysis. CMR feature-tracking (CMR-FT) analysis is emerging as a feasible semi-automatic tool for the evaluation of LA volumes and function. Purpose To investigate the potential of LA-focused CMR cine images using LA CMR-FT analysis. Methods 100 consecutive patients clinically referred to CMR were included in this prospective, observational, multicenter study. LA volumes (LAVmax, LAVmin), emptying fraction (EF), atrial strain reservoir (ɛs), conduit (ɛe), booster (ɛa) and strain rate reservoir (SRɛs) were calculated by CMR-FT analysis on both standard and LA-focused 2- and 4-chamber long-axis cine images. Manual segmentation of a short-axis cine stack covering the LA was used as the reference method (RefMeth) for LA volumes and EF. Results In comparison to the RefMeth, the standard acquisitions underestimated LA volumes (LAVmax: bias = −8ml, LOA = +20, −35ml; LAVmin: bias = −6 ml, LOA = +15, −27ml) and slightly overestimated EF (bias = +3%, LOA = +17, −11%). Conversely, LA-focused images provided a more accurate estimation (LAV max bias = −1ml, LOA = +11, −9ml; LAV min bias = −2ml, LOA = +12, −7ml) and EF (bias = −2%, LOA = +9, −12%). All three LA strain (εs: bias 7%, LOA = 25, −11%; εe: bias 4%, LOA = 15, −8%; εa: bias 3%, LOA = 14, −8%) and SRεs (bias 0.2 s–1, LOA = 1.13, −0.7 s–1) were significantly higher in standard vs LA-focused images (all p<0.001). Conclusions Assessment of LA volumes using CMR-FT applied to dedicated LA-focused long-axis cine images is more accurate than the use of standard acquisitions. LA strain and SRɛs obtained from LA-focused images are significantly lower than those obtained from standard LA acquisitions, possibly due to the inclusion in LA-focused images of LA posterior wall, where pulmonary veins convey and atrial deformation is blunted. Funding Acknowledgement Type of funding sources: None.
更多
查看译文
关键词
atrial volumes,left atrial,feature-tracking,left-atrial
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要