谷歌浏览器插件
订阅小程序
在清言上使用

Warfarin Reversal with Four-Factor Prothrombin Complex Concentrate for Left Ventricular Assist Device Conversion Surgery Monitored by TEG6s: A Case Report.

Curēus(2022)

引用 0|浏览5
暂无评分
摘要
Left ventricular assist devices (LVADs) require careful therapeutic anticoagulation with warfarin to prevent pump thrombosis. However, the best method to reverse warfarin for elective LVAD conversion surgery with massive bleeding remains unclear. We report the case of a 39-year-old Japanese man who was administered a four-factor prothrombin complex concentrate (4F-PCC) as warfarin reversal when he underwent conversion surgery from paracorporeal LVAD to implantable LVAD. 4F-PCC with co-administration of vitamin K reduced the international normalized ratio and R time in TEG6s (Haemonetics Corporation, USA) immediately. The effect was prolonged, and good hemostasis was achieved. 4F-PCC with vitamin K provided good hemostasis in our patient; therefore, 4F-PCC could be a useful tool for elective LVAD conversion surgery with expected massive bleeding and requiring immediate warfarin reversal.
更多
查看译文
关键词
point -of -care monitoring,left ventricular assist devices,warfarin reversal,thromboelastography,four factor prothrombin complex concentrate
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要