Warfarin Reversal with Four-Factor Prothrombin Complex Concentrate for Left Ventricular Assist Device Conversion Surgery Monitored by TEG6s: A Case Report.
Curēus(2022)
摘要
Left ventricular assist devices (LVADs) require careful therapeutic anticoagulation with warfarin to prevent pump thrombosis. However, the best method to reverse warfarin for elective LVAD conversion surgery with massive bleeding remains unclear. We report the case of a 39-year-old Japanese man who was administered a four-factor prothrombin complex concentrate (4F-PCC) as warfarin reversal when he underwent conversion surgery from paracorporeal LVAD to implantable LVAD. 4F-PCC with co-administration of vitamin K reduced the international normalized ratio and R time in TEG6s (Haemonetics Corporation, USA) immediately. The effect was prolonged, and good hemostasis was achieved. 4F-PCC with vitamin K provided good hemostasis in our patient; therefore, 4F-PCC could be a useful tool for elective LVAD conversion surgery with expected massive bleeding and requiring immediate warfarin reversal.
更多查看译文
关键词
point -of -care monitoring,left ventricular assist devices,warfarin reversal,thromboelastography,four factor prothrombin complex concentrate