Chrome Extension
WeChat Mini Program
Use on ChatGLM

Anoxic-Aerobic-Anoxic sequencing batch reactor for enhanced nitrogen removal

Bioresource Technology(2022)

Cited 11|Views5
No score
Abstract
An anoxic-aerobic-anoxic process was established to achieve simultaneous removal of organic carbon and nitrogen from wastewater in a sequencing batch reactor. The optimum conditions were attained at a DO of 1.5 mg/ L with 1 h pre-anoxic and post-anoxic periods. TOC, NH4+-N, and TN removal efficiencies were 98.76 +/- 0.95 %, 98.52 +/- 0.48 %, and 88.23 +/- 0.62 %, respectively, at optimum conditions. Breakpoints in the pH, DO, and ORP curves provided a clear understanding of biochemical reactions happening in the reactor. Inhibition studies showed that 27.69 % of NH4+-N was removed through nitrogen removal pathways such as heterotrophic nitrification or direct conversion, and 20.55 % of TN was removed through aerobic denitrification. Microbial community analysis confirmed the presence of heterotrophic nitrifiers and aerobic denitrifiers. This study highlighted that the varied redox conditions offered by limited aeration would be beneficial for nitrogen removal, thereby reducing the energy usage and operating costs.
More
Translated text
Key words
Biological nitrogen removal,Sequencing batch reactor,Aeration pattern,Simultaneous nitrification-denitrification,Dissolved oxygen
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined