谷歌浏览器插件
订阅小程序
在清言上使用

Risk Factors for Incomplete Aortic Remodeling with Stent-Assisted Balloon-Induced Intimal Disruption and Relamination in Aortic Dissection Repair for Complicated Aortic Dissection: Results of a Multicenter Study.

Journal of endovascular therapy(2022)

引用 2|浏览5
暂无评分
摘要
PURPOSE:The STABILISE technique has extended the treatment of aortic dissection to the thoracoabdominal aorta to achieve complete aortic remodeling. The aim of this multicenter study was to analyze the short- and midterm anatomical results of the STABILISE technique.MATERIALS AND METHODS:We retrospectively analyzed patients treated with the STABILISE technique for complicated aortic dissection at 3 French academic centers. The aortic diameter at different levels was measured preoperatively, postoperatively, and at 1 year.RESULTS:Between 2018 and 2020, 58 patients, including 47 men (average patient age: 60±11 years), were treated for type B aortic dissection in 34 cases and residual aortic dissection after type A repair in 24 cases. Three (5.2%) patients died postoperatively. Complete aortic remodeling (false lumen thrombosis and complete reapposition of the intimal flap) was achieved in 45/55 patients (81.8%), and false lumen thrombosis in the thoracic aorta was achieved in 52/55 patients (94.5%). At 1 year, with a computed tomographic (CT) scan available for 98.2% (54/55) of patients, we observed a significant decrease in the maximal thoracic aortic diameter and a significant increase in the aortic diameter at the bare-stent level compared with the preoperative CT scan. Severe aortic angulation (p=0.024) was a risk factor for incomplete aortic remodeling and significantly increased the aortic diameter (p=0.032). Chronic aortic dissection was associated with an increased risk of incomplete aortic remodeling (p=0.002).CONCLUSIONS:STABILISE for complicated aortic dissection results in false lumen thrombosis, complete reapposition of the intimal flap, and a decrease in the maximum aortic diameter in most cases. Incomplete reapposition of the intimal flap, which is more frequent in cases of chronic aortic dissection and severe aortic angulation, is a risk factor for a significant increase in the aortic diameter at the bare-stent level, and this risk justifies close follow-up and better patient selection.CLINICAL IMPACT:STABILISE technique for complicated aortic dissection results in false lumen thrombosis, complete aortic remodeling and a decrease in the maximum aortic diameter in most cases. At the bare-stent level, incomplete reapposition of the intimal flap, more frequent in chronic aortic dissection and severe aortic angulation, is a risk factor for an increased aortic diameter. This finding justifies close follow-up and better patient selection; thus, the STABILISE technique should be used with care in chronic aortic dissection and severe aortic angulation.
更多
查看译文
关键词
STABILISE technique,aortic dissection,TEVAR,anatomical results,aneurysm evolution,risk factors
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要