Thermal-insulation and Temperature-Resistant Foamed Gel for Thermal Management of Heavy Oil Steam Flooding

Journal of molecular liquids(2022)

引用 4|浏览9
暂无评分
摘要
Due to the serious gravity overriding and large heat loss, thermally insulated and temperature-resistant plugging agents are highly desired in steam flooding. In this work, a physically-crosslinked clayey foamed hydrogel Bent/PAM, with low thermal conductance, high thermal stability and good mobility, was synthesized by one-pot process, using bentonite as matrix and polyacrylamide as cross-linking agent. Bent/PAM has hierarchically 3D porous structure and double network. Specifically, abundant mesosized air chambers in gel endows it with low thermal conductivity. And, its outer clay percolated network with micro-sized meshes provides a temperature-resistant coating, while the inner polymer-clay composite network with nano-sized meshes affords a high strength. On the other hand, the easily slidable clay platelets make its outer percolated network turn into a lubricating film, offering the foamed gel with low friction and viscosity. From the core flooding experiments, the Bent-5/PAM-2 gel (the optimal sample) possesses large plugging rate, plugging intensity and oil recovery (EOR), up to 83.7%, 321 KPa and 63.5%, respectively.(c) 2022 Elsevier B.V. All rights reserved.
更多
查看译文
关键词
Thermal insulation,Foamed gel,Heavy oil,Profile control,Heat loss
AI 理解论文