Experimental analysis of zero-natural-frequency damper for transmission line large cross project based on NES

Journal of Physics: Conference Series(2021)

引用 0|浏览1
暂无评分
摘要
Abstract The operation experience of transmission line large cross project shows that the traditional anti-aeolian-vibration devices had poor adaptability to complex terrain and micro meteorological conditions, and they were difficult to meet the application requirements of super large cross project at this stage. A zero-natural-frequency damper was designed by introducing nonlinear energy sink in this paper, and the solid prototypes were processed. According to the actual design parameters of conductor using in a large cross project, the anti-vibration effect was tested by using the indoor simulation test span. The test results showed that the anti-vibration effect of the scheme based on the zero-natural-frequency damper could meet the needs of practical engineering. The installation of this damper could improve conductors’ and fittings’ adaptability to complex terrain and enhance the wind and anti-vibration ability of transmission line.
更多
查看译文
关键词
transmission line,zero-natural-frequency zero-natural-frequency