Strategy for Vacuum Insulation Tests of MITICA 1 MV Electrostatic Accelerator

IEEE transactions on plasma science(2022)

引用 4|浏览0
暂无评分
摘要
The electrical insulation of the Megavolt ITER Injector and Concept Advancement (MITICA) beam source (BS) at 1 MV in vacuum is a challenging issue, which could not be fully addressed so far on the basis of experimental results and of theoretical models available in literature. A specific high-voltage (HV) test campaign is being prepared to validate and optimize the voltage holding capability of the BS insulation under realistic conditions, using full-size mockup electrodes reproducing in detail the geometry of the BS and accelerator. The proposed test strategy will address both the single-gap and the multistage insulation, so as to obtain a verification of voltage holding at 1 MV before the installation of the real components. This approach is intended to reduce the risk related to the HV insulation at 1 MV and, if necessary, to allow the development of effective corrections. In this article, the test motivations and requirements are defined, and the electrode implementation and diagnostic setup are described. Finally, the test configurations and the experimental procedure are discussed.
更多
查看译文
关键词
Insulation,Electrodes,Electrostatics,Electric breakdown,Breakdown voltage,Geometry,Plasmas,High-voltage holding,neutral beam injector (NBI)