Post-MRI transrectal micro-ultrasonography of transition zone PI-RADS > 2 lesions for biopsy guidance

European radiology(2022)

Cited 0|Views3
No score
Abstract
Objective To prospectively determine the value of post-MRI micro-ultrasonography (microUS) in the diagnosis of transition zone (TZ) significant prostate cancer (sPCa). Patients and methods Eighty-four consecutive men (66 ± 6.3 years) with a mean PSA level of 10.2 ± 7.4 ng/mL and at least one TZ-PI-RADS > 2 lesion were included. All patients had MRI-directed microUS and biopsy. Sensitivity and specificity of post-MRI microUS to visualize PI-RADS > 2 TZ lesions, the cancer detection rate of TZ-sPCa, and tumor characteristics according to their visibility on microUS were evaluated. Interreader agreement for detecting microUS+ lesions was evaluated using Cohen’s kappa test. Results Of the 92 PI-RADS > 2 lesions, 71 (71/92; 77%) were visible on microUS and biopsy was performed without image fusion, which was required for the 21 invisible lesions (21/92; 22.8%). TZ-sPCa detection rate was 51.1% (47/92). Sensitivity and specificity of MRI-directed microUS were 83% (39/47; 95% CI: 69.2–92.4%) and 28.9% (13/45; 95% CI: 16.4–44.3%), on a per-lesion basis and 86.4% (38/45; 95% CI: 72.6–94.8%) and 27.5% (11/40; 95% CI: 14.6–43.9%) on a per-patient basis. Visible tumors on microUS exhibited a larger volume and a lower mean ADC value than non-visible tumors (15.8 ± 5.1 vs. 12.5 ± 3.6 mm and 0.82 ± 1.1 × 10 3 vs. 0.9 ± 1.4 × 10 −3 mm 2 /s) ( p = 0.02). Non-visible tumors showed a heterogeneous non-specific echotexture or were masked by the shadowing caused by corpora amylacea. Interreader agreement was almost perfect (kappa = 0.88; 95% CI: 0.79–0.95). The main limitation is the single-center feature of the study. Conclusion MRI-targeted transrectal microUS is effective to detect TZ-sPCa. TRUS-MRI image fusion helps overcome limitations due to TZ tissue heterogeneity. Key Points microUS can visualize the majority of MRI-detected PI-RADS > 2 TZ lesions (sensitivity = 83%). Interreader agreement of MRI-directed microUS in the detection of TZ lesions appears excellent (kappa = 0.88). In 77% of PI-RADS > 2 TZ lesions, biopsy was performed under microUS visual control. MRI fusion system was only used to overcome limitations due to tissue heterogeneity of benign prostatic hyperplasia.
More
Translated text
Key words
Ultrasonography,Prostate,Biopsy,Magnetic resonance imaging,Prostatic neoplasms
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined