Corneal Nerve Parameter Reference Values for Chinese Adults Assessed by Corneal Confocal Microscopy

Journal of diabetes research(2022)

引用 3|浏览22
暂无评分
摘要
Background. Confocal corneal microscopy is an excellent new noninvasive tool for assessing diabetic peripheral neuropathy. We aimed to investigate the clinical variables associated with corneal nerve parameters and establish reference values for clinical use in healthy Chinese adults. Methods. The study enlisted 257 healthy volunteers (137 females and 120 males) from two clinical academic centers in China. Two experts captured and selected images of the central corneal subbasal nerve plexus at each center using the same corneal confocal microscopy instrument according to a commonly adopted protocol. Corneal nerve fiber density (CNFD), corneal nerve branch density (CNBD), and corneal nerve fiber length (CNFL) were measured using fully automated software (ACCMetrics). The correlation between clinical indicators and confocal corneal microscopy measures was determined using partial correlation. Quantile regression was used to calculate reference values and estimate the effects of clinical factors on the normative values of confocal corneal microscopy measures. Results. Females had significantly higher CNFD, CNBD, and CNFL than males. There was no correlation between age, glycated hemoglobin (HbA1c), height, weight, body mass index (BMI), and any corneal nerve fiber parameter in both sexes. In either sex, age, weight, height, BMI, and HbA1c did not affect the 0.05th quantile values of any corneal nerve parameter. Conclusions. This study establishes sex-adjusted reference values for corneal confocal microscopy measures in Chinese adults and provides a reference for clinical practice and research with this technique.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要