Mitigation of Current Distortion for GaN-Based CRM Totem-Pole PFC Rectifier With ZVS Control

IEEE Open Journal of Power Electronics(2021)

Cited 9|Views0
No score
Abstract
The GaN-based critical conduction mode (CRM) totem-pole power factor correction (PFC) converter with full-line-cycle zero voltage switching (ZVS) is a promising candidate for high-efficiency front-end rectifiers. However, the input current can be degraded by line-cycle current distortion and ac line zero-crossing current spikes, and maintaining reliable ZVS control is difficult in noise-susceptible high-frequency environments. In this paper, a detailed analysis of the current distortion issues in a GaN-based CRM totem-pole PFC with digital ZVS control is provided, and effective approaches are proposed to mitigate different kinds of current distortion and ensure stable ZVS control under high-frequency operation. The proposed solutions have the advantages of straightforward implementation and do not increase the control complexity. The current distortion issues are demonstrated in two GaN-based CRM totem-pole PFC prototypes, a 1.5 kW PFC for data centers and a 100 W PFC in a 6.78 MHz wireless charging power supply for consumer electronics. The proposed methods are experimentally verified with effective mitigation of the current distortion and improvement of the converter power efficiency.
More
Translated text
Key words
GaN,CRM,totem-pole PFC,ZVS control,current distortion,data centers,wireless charging