Heart Rate Monitor Agreement in Breast Cancer Survivors in A Community-based Exercise Program

Medicine and science in sports and exercise(2021)

引用 0|浏览3
暂无评分
摘要
Appropriate exercise intensity, often expressed as target heart rate (HR), is critical to effecting change in symptom burden in breast cancer survivors (BCS). Traditional chest-worn monitors, despite their well-documented validity, may be inconvenient in unsupervised settings due to necessary receivers and participant discomfort. Commercially-available wearable sensors may represent an accessible alternative to HR monitoring in community-based exercise settings. PURPOSE: To examine the agreement between the Fitbit Inspire HR and Polar chest monitor for HR measurement in BCS at different stages of exercise in a community-based program. METHODS: BCS (N = 9; aged 38-72 years) were randomized to a 12-week moderate intensity (45-75% HR reserve) pilot aerobic exercise program. HR was concurrently measured using a Polar chest strap monitor and wrist-worn Fitbit Inspire HR in 5 stages: pre-exercise seated rest; midpoint of a 5-minute warmup; midpoint of moderate intensity exercise; midpoint of a 5-minute cool-down; after a 5-minute seated recovery. Agreement between HR measurements was assessed using Lin’s concordance correlation coefficient (rc). Relative error rates were calculated to indicate differences across exercise session stages. RESULTS: Across sessions (n = 187), HR ranged from 55 to 139 beats per minute. Agreement between the Polar monitor and Fitbit Inspire HR was highest during seated rest (pre-exercise, rc = 0.74, 95%CI [0.67, 0.80]; post-exercise, rc = 0.90, 95%CI [0.86, 0.92]) followed by the midpoint of moderate intensity exercise (rc = 0.63, 95%CI [0.54, 0.70]). Agreement was lowest during “transitionary” periods—i.e., warmup (rc = 0.37, 95% [0.25, 0.49]) and cool-down (rc = 0.43, 95% [0.32, 0.53]). Mean relative error rates ranged from -4.30% to 3.27% and were greatest during the warmup stage (RER = -4.3 ± 12.06%). CONCLUSION: This study provides novel data on HR monitor agreement in a community-based exercise setting and in a clinical population. Results indicate moderate agreement between Fitbit Inspire HR and Polar HR monitors during steady-state, moderate intensity aerobic exercise. While Fitbit alone may provide an estimate of exercise HR, it is likely not precise enough for accurate HR monitoring in exercise prescription.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要