Anesthetic Induction and Endotracheal Intubation in the Sitting Position Due to the Fixed Forearm Caught by a Meat Grinder.
Brazilian journal of anesthesiology/Brazilian Journal of Anesthesiology(2023)
摘要
A male patient was scheduled for urgent amputation of his right forearm. His right forearm was stuck inside the insertion slot of a meat grinder, resulting in severe pain to his injured arm. His upper body could not move to sit in a semi-upright position. An endotracheal tube was successfully placed after rapid sequence intubation using a video laryngoscope from behind the patient on the first attempt. This case report is the first documentation of successful anesthetic induction with subsequent endotracheal intubation using a video laryngoscope from behind an injured patient whose upper body was upright with limited positioning.
更多查看译文
关键词
Anesthesia,Sitting position,Tracheal intubation,Video laryngoscope
AI 理解论文