谷歌浏览器插件
订阅小程序
在清言上使用

Diagnostic Performance of a Lower-dose Contrast-Enhanced 4D Dynamic MR Angiography of the Lower Extremities at 3 T Using Multisegmental Time-Resolved Maximum Intensity Projections

Journal of magnetic resonance imaging JMRI(2021)

引用 2|浏览7
暂无评分
摘要
Background For peripheral artery disease (PAD), MR angiography (MRA) is a well-established diagnostic modality providing morphologic and dynamic information comparable to digital subtraction angiography (DSA). However, relatively large amounts of contrast agents are necessary to achieve this. Purpose To evaluate the diagnostic accuracy of time-resolved 4D MR-angiography with interleaved stochastic trajectories (TWIST-MRA) by using maximum intensity projections (MIPs) of dynamic images acquired with reduced doses of contrast agent. Study Type Retrospective. Population Forty adult PAD patients yielding 1088 artery segments. Field Strength/Sequence A 3.0 T, time-resolved 4D MR-angiography with TWIST-MRA and MIP of dynamic images. Assessment DSA was available in 14 patients (256 artery segments) and used as reference standard. Three-segmental MIP reconstructions of TWIST-images after administration of 3 mL of gadolinium-based contrast agent (Gadoteridol/Prohance (R), 0.5 M) per anatomical level (pelvis, thighs, and lower legs) yielded 256 artery segments for correlation between MRA and DSA. Three independent observers rated image quality (scale: 1 [nondiagnostic] to 4 [excellent]) and the degree of venous overlay (scale: 0 [none] to 2 [significant]) for all segments. Diagnostic accuracy for the detection of >50% stenosis and artery occlusion was calculated for all observers. Statistical Tests Binary classification test (sensitivity, specificity, positive/negative predictive values, diagnostic accuracy). Intraclass correlation coefficients (ICCs), logistic regression analysis with comparison of areas under the receiver-operating-characteristics (ROC) curves (AUCs) with the DeLong method. Bland-Altman-comparison. Results High diagnostic performance was achieved for the detection of >50% stenosis (sensitivity 92.9% [84.3-99.9% (95%-CI)] and specificity 98.5% [95.7-99.8% (95%-CI)]) and artery occlusion (sensitivity 93.1% [77.2-99.2% (95%-CI)] and specificity 99.1% [96.9-99.9% (95%-CI)]). Inter-reader agreement was excellent with ICC values ranging from 0.95 to 1.0 for >50% artery stenosis and occlusion. Image quality was good to excellent for both readers (3.41 +/- 0.72, 3.33 +/- 0.65, and 3.38 +/- 0.61 [mean +/- SD]) with good correlation between observer ratings (ICC 0.71-0.81). No significant venous overlay was observed (0.06 +/- 0.24, 0.23 +/- 0.43 and 0.11 +/- 0.45 [mean +/- SD]). Data Conclusion MIPs of dynamic TWIST-MRA offer a promising diagnostic alternative necessitating only reduced amounts (50%) of gadolinium-based contrast agents for the entire runoff vasculature. Evidence Level 3 Technical Efficacy Stage 2
更多
查看译文
关键词
peripheral arterial disease,time&#8208,resolved MR angiography,time&#8208,resolved angiography with interleaved stochastic trajectories,digital subtraction angiography
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要