谷歌浏览器插件
订阅小程序
在清言上使用

Comparing Method Analysis for Lower Steam Temperature of 660MW Supercritical Lignitic Boiler

PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON GREEN MATERIALS AND ENVIRONMENTAL ENGINEERING (GMEE 2015)(2016)

引用 0|浏览23
暂无评分
摘要
The problem of lower main steam temperature(MST) of a supercritical boiler designed for burning high moisture lignite is analyzed. By comparing to another structure-similar subcritical boiler, the effects of coal, furnace size, combustion mode and heating surface distribution are studied. The results show that the major cause of this lower MST problem is unduly decline of high temperature heating area due to over-estimating the heat transfer capability of the upper furnace water wall of the supercritical boiler. At last, this document suggests to the increase the size of rear part of partition platen superheater(SH) to solve the problem and has a certain actual guiding reference.
更多
查看译文
关键词
component,supercritical unit,boiler,low main steam temperature,super heater
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要