谷歌浏览器插件
订阅小程序
在清言上使用

Lawrence Berkeley National Laboratory Recent Work Title Exploring Cosmic Origins with CORE : The Instrument Permalink

P. de Bernardis,P. A. R. Ade,J. J. A. Baselmans, S. E., Battistelli,A. Benoit,M. Bersanelli,A. Bideaud, M., Calvo,F. J. Casas, G. Castellano,A. Catalano,I. Charles,I. Colantoni, F. Columbro,A. Coppolecchia,M. Crook, G., D’Alessandro,M. De Petris,J. Delabrouille,S. Doyle, C., Franceschet, A. Gomez,J. Goupy, S. Hanany, M. Hills, L., Lamagna, J. Macias-Perez,B. Maffei, S. Martin, E., Martinez-Gonzalez,S. Masi, D. McCarthy,A. Mennella,A. Monfardini,F. Noviello, A. Paiella,F. Piacentini, Piat,G. Pisano, G. Signorelli, C. Y. Tan,A. Tartari, N., Trappe, S. Triqueneaux,C. Tucker,G. Vermeulen, K., Young, M. Zannoni, A. Achúcarro, R. Allison, Ashdown,M. Ballardini,A. J. Banday, R. Banerji,J. Bartlett,N. Bartolo,S. Basak,A. Bonaldi, Bonato,J. Borrill, F. Bouchet,F. Boulanger, T., Brinckmann,M. Bucher,C. Burigana, A. Buzzelli,Z. Y. Cai,C. S. Carvalho,A. Challinor, J. Chluba, S., Clesse,G. De Gasperis,G. De Zotti,E. Di Valentino,J. M. Diego, J. Errard, S. Feeney,R. Fernandez-Cobos,F. Finelli,F. Forastieri,S. Galli, R. Génova-Santos,M. Gerbino,J. González-Nuevo, S. Hagstotz, J., Greenslade,W. Handley,C. Hernández-Monteagudo, Hervias-Caimapo,E. Hivon,K. Kiiveri, T. Kisner, Kitching,M. Kunz,H. Kurki-Suonio,A. Lasenby, Lattanzi,J. Lesgourgues,A. Lewis,M. Liguori, V., Lindholm, G. Luzzi,C. J. A. P. Martins,A. Melchiorri,J. B. Melin,D. Molinari,P. Natoli,M. Negrello, A., Notari,D. Paoletti,G. Patanchon,L. Polastri, Polenta, A. Pollo, V. Poulin, M. Quartin, Remazeilles,M. Roman,J. A. Rubiño-Martín

semanticscholar(2017)

引用 0|浏览8
暂无评分
摘要
We describe a space-borne, multi-band, multi-beam polarimeter aiming at a precise and accurate measurement of the polarization of the Cosmic Microwave Background. The instrument is optimized to be compatible with the strict budget requirements of a mediumsize space mission within the Cosmic Vision Programme of the European Space Agency. The instrument has no moving parts, and uses arrays of diffraction-limited Kinetic Inductance Detectors to cover the frequency range from 60 GHz to 600 GHz in 19 wide bands, in the focal plane of a 1.2 m aperture telescope cooled at 40 K, allowing for an accurate extraction of the CMB signal from polarized foreground emission. The projected CMB polarization survey sensitivity of this instrument, after foregrounds removal, is 1.7 μK·arcmin. The design is robust enough to allow, if needed, a downscoped version of the instrument covering the 100 GHz to 600 GHz range with a 0.8 m aperture telescope cooled at 85 K, with a projected CMB polarization survey sensitivity of 3.2 μK·arcmin.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要