谷歌浏览器插件
订阅小程序
在清言上使用

E-024 Low profile transradial pipeline embolization

Journal of NeuroInterventional Surgery(2019)

引用 0|浏览12
暂无评分
摘要
PurposeRetrospective review of all Medtronic Pipeline Flex flow diverting stent placement at single center with attention to guiding catheter selection, technical success, intracranial complications, access site complications and length of procedure. Summarize technical advantages and limitations of each access strategy and present a simplified 6 French triaxial system for flow diversion stent placement via a transradial/trans-ulnar approach. We also present some tips and tricks to optimize procedural success including transulnar access and direct radial access.Materials and methodsSingle Center retrograde suspect of review of all Medtronic Pipeline Embolization Flex procedures performed between October 2015-March 2019 via arm access (radial or ulnar). Three different 6F constructs were used for arm access: Direct radial access with long sheath–Terumo destination slender Benchmark radial access Codman Envoy DA radial access Primary endpoints include time from radial accessed to target lesion, time from radial access to pipeline embolization deployment, technical failure requiring alternative access, intracranial complications, radial access site complications, occlusion rates at longest available follow-up were delayed neurologic complications.ResultsA total of 23 patients were included in this retrospective analysis. Average patient age and male gender were 60.4 years and 22% respectively. A total of 31 devices were used to treat a total of 30 aneurysms. Average aneurysm size was 7 mm. Primary placement of a flow diverting stent was performed in a majority of patients with adjunctive coil placement was performed in 13.1% procedures. Post stent placement balloon angioplasty was performed in 34% procedures. No intracranial complications including dissection, intracranial hemorrhage, symptomatic embolic stroke were identified. Major access site complications and symptomatic delayed radial artery occlusion were not identified in any patients undergoing arm access. Furthest available follow-up was on an average of 9.8 months. Complete occlusion was achieved in 70% patients (we anticipate further occlusion by one year). Additional pipeline embolization devices were required in 1 patient, at 18 months. Foley catheter and arterial line placement, 35% and 22%, respectively.LimitationsSingle center retrospective review, short interval follow-up (less than 1 year), and some patients lost to follow-up.Conclusion6 French Triaxial Trans-radial (or ulnar access) can be used in placement of a Pipeline Embolization Flex device with low associated complications and high technical success.DisclosuresS. Satti: 2; C; Stryker Neurovascular, Medtronic Neurovascular, Penumbra Neurovascular, Cerenovus Neurovascular, Terumo. T. Eden: None.
更多
查看译文
关键词
transradial pipeline embolization
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要