The hydraulic hammer effect in solar tower fluid circuit temperature controller

IFAC-PapersOnLine(2017)

引用 0|浏览7
暂无评分
摘要
This article addresses the possible occurrence of hydraulic hammer effects in solar power towers and the limitations they impose on the response bandwidth of the control loop that governs the valve actuating on heating fluid flow. The partial differential equations that model the traveling waves associated to the hammer effect are solved with different methods. A finite dimensional approximation of the exact solution, by a transfer function with a finite number of poles is obtained. It is concluded that, for the speed of response of the temperature controller associated to the valve, there is no danger of inducing hydraulic hammer effects that can damage the equipment.
更多
查看译文
关键词
Power plants,constraint,security monitoring,Control,solar plants,hammer effect,modelling of infinite dimensional systems