Hip Joint Torsional Loading Before and After Cam Femoroacetabular Impingement Surgery.

AMERICAN JOURNAL OF SPORTS MEDICINE(2019)

引用 20|浏览14
暂无评分
摘要
Background: Surgical management of cam femoroacetabular impingement (FAI) aims to preserve the native hip and restore joint function, although it is unclear how the capsulotomy, cam deformity, and capsular repair influence joint mechanics to balance functional mobility. Purpose: To examine the contributions of the capsule and cam deformity to hip joint mechanics. Using in vitro, cadaveric methods, we examined the individual effects of the surgical capsulotomy, cam resection, and capsular repair on passive range of motion and resistance of applied torque. Study Design: Descriptive laboratory study. Methods: Twelve cadaveric hips with cam deformities were skeletonized to the capsule and mounted onto a robotic testing platform. The robot positioned each intact hip in multiple testing positions: (1) extension, (2) neutral 0 degrees, (3) flexion 30 degrees, (4) flexion 90 degrees, (5) flexion-adduction and internal rotation (FADIR), and (6) flexion-abduction and external rotation. Then the robot performed applicable internal and external rotations, recording the neutral path of motion until a 5-N center dot m of torque was reached in each rotational direction. Each hip then underwent a series of surgical stages (T-capsulotomy, cam resection, capsular repair) and was retested to reach 5 N center dot m of internal and external torque again after each stage. During the capsulotomy and cam resection stages, the initial intact hip's recorded path of motion was replayed to measure changes in resisted torque. Results: Regarding changes in motion, external rotation increased substantially after capsulotomies, but internal rotation only further increased at flexion 90 degrees (change +32%, P = .001, d = 0.58) and FADIR (change +33%, P < .001, d = 0.51) after cam resections. Capsular repair provided marginal restraint for internal rotation but restrained the external rotation compared with the capsulotomy stage. Regarding changes in torque, both internal and external torque resistance decreased after capsulotomy. Compared with the capsulotomy stage, cam resection further reduced internal torque resistance during flexion 90 degrees (change -45%, P < .001, d = 0.98) and FADIR (change -37%, P = .003, d = 1.0), where the cam deformity accounted for 21% of the intact hip's torsional resistance in flexion 90 degrees and 27% in FADIR. Conclusion: Although the capsule played a predominant role in joint constraint, the cam deformity provided 21% to 27% of the intact hip's resistance to torsional load in flexion and internal rotation. Resecting the cam deformity would remove this loading on the chondrolabra
更多
查看译文
关键词
cam,femoroacetabular impingement,capsule,robot,in vitro
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要