谷歌浏览器插件
订阅小程序
在清言上使用

Impacto De La Retirada De Los Lavabos En Una Unidad De Cuidados Intensivos Sobre Los Aislamientos Por Bacilos Gramnegativos No Fermentadores En Pacientes Con Ventilación Mecánica Invasiva

Medicina clínica(2019)

引用 3|浏览5
暂无评分
摘要
Introduction and objective: Contamination of sinks, even due to their underuse, is associated with the transmission of non-fermenting gram-negative bacilli (NFGNB) to patients in Augmented Care Units. After previous monitoring with environmental and patient samples, we now explore the impact of removing sinks from ICU cubicles on incidental isolations related to health care in bronchoaspirate samples of patients with invasive mechanical ventilation (IMV). Material and methods: Quasi-experimental study, before-and-after, pre-intervention annuities April 2014-2016 and post-intervention April 2016-2017. Incidence densities per 1,000 days of IMV were studied, comparing by the exact method based on the binomial distribution and estimating the incidence density ratio. Results: The incidence densities per 1,000 days of IMV of isolations by NFGNB in bronchoaspirate samples of the pre and post-intervention periods were 11.28 and 1.9, respectively. This implies a post-intervention incidence density 5.90 times lower than before (95% CI: 1.49-51.05, P= .003). Conclusions: Despite of the limitations of the design, the removal of sinks showed a reduction of the isolations. (C) 2018 Elsevier Espana, S.L.U. All rights reserved.
更多
查看译文
关键词
Monitoring,Non-fermenting gram-negative bacilli,Bronchoaspirate sample,Sink,Intensive care unit,Infection control