Chrome Extension
WeChat Mini Program
Use on ChatGLM

Midterm Outcomes after Aortic Valve Neocuspidization with Glutaraldehyde-Treated Autologous Pericardium.

Journal of Thoracic and Cardiovascular Surgery(2018)SCI 1区SCI 2区

Address for reprints: Shigeyuki Ozaki

Cited 218|Views17
Abstract
Objective: We had previously reported the short-term results of the aortic valve neocuspidization (AVNeo) procedure. We have now evaluated the midterm results with the longest follow-up of 118 months. Methods: From April 2007 through December 2015, 850 patients were treated with AVNeo using autologous pericardium. Medical records of these patients were retrospectively reviewed. The procedure was on the basis of independent tricuspid replacement using autologous pericardium. The distances between the commissures were measured with an original sizing device, the pericardial cusp was trimmed using an original template, and then sutured to the annulus. Results: There were 534 patients with aortic stenosis, 254 with aortic regurgitation, 61 with aortic stenoregurgitation, 19 with infective endocarditis, and 5 with a previous aortic valve procedure. Besides 596 patients with tricuspid aortic valve, 224 patients had bicuspid valve, 28 had unicuspid valve, and 2 had quadricuspid valve. There were 444 male and 406 female patients. The median age was 71 (range, 13-90) years old. Preoperative echocardiography revealed a peak pressure gradient average of 68.9 +/- 36.3 mm Hg with aortic stenosis. Surgical annular diameter was 20.9 +/- 3.3 mm. There was no conversion to a prosthetic valve replacement. There were 16 in-hospital mortalities. Postoperative echocardiography revealed a peak pressure gradient average of 19.5 +/- 10.3 mm Hg 1 week after surgery and 15.2 +/- 6.3 mm Hg 8 years after surgery. Fifteen patients needed reoperation (13 infective endocarditis, 1 break of thread, and 1 tear of cusp case). The mean follow-up period was 53.7 +/- 28.2 months. Actuarial freedom from death, cumulative incidence of reoperation, and that of recurrent moderate aortic regurgitation or greater was 85.9%, 4.2%, and 7.3%, respectively, with the longest follow-up of 118 months. Conclusions: The midterm outcomes of AVNeo using autologous pericardium were satisfactory in 850 patients with various aortic valve diseases. However, further randomized, multicenter prospective studies are needed to confirm the results of the current study.
More
Translated text
Key words
aortic valve disease,autologous pericardium,aortic valve surgery
PDF
Bibtex
AI Read Science
AI Summary
AI Summary is the key point extracted automatically understanding the full text of the paper, including the background, methods, results, conclusions, icons and other key content, so that you can get the outline of the paper at a glance.
Example
Background
Key content
Introduction
Methods
Results
Related work
Fund
Key content
  • Pretraining has recently greatly promoted the development of natural language processing (NLP)
  • We show that M6 outperforms the baselines in multimodal downstream tasks, and the large M6 with 10 parameters can reach a better performance
  • We propose a method called M6 that is able to process information of multiple modalities and perform both single-modal and cross-modal understanding and generation
  • The model is scaled to large model with 10 billion parameters with sophisticated deployment, and the 10 -parameter M6-large is the largest pretrained model in Chinese
  • Experimental results show that our proposed M6 outperforms the baseline in a number of downstream tasks concerning both single modality and multiple modalities We will continue the pretraining of extremely large models by increasing data to explore the limit of its performance
Try using models to generate summary,it takes about 60s
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Related Papers
Data Disclaimer
The page data are from open Internet sources, cooperative publishers and automatic analysis results through AI technology. We do not make any commitments and guarantees for the validity, accuracy, correctness, reliability, completeness and timeliness of the page data. If you have any questions, please contact us by email: report@aminer.cn
Chat Paper
GPU is busy, summary generation fails
Rerequest