Bone and Soft Tissue Response in Bone-Level Implants Restored with Platform Switching: A 5-Year Clinical Prospective Study

˜The œInternational journal of oral and maxillofacial implants/˜The œinternational journal of oral & maxillofacial implants(2017)

引用 10|浏览3
暂无评分
摘要
Purpose; The aim of this prospective study was to evaluate radiographic levels of peri-implant bone crest as well as soft tissue response, papilla height, and buccal mucosa recession, in bone-level implants restored with platform switching after 1-year and 5-year follow-ups. Materials and Methods: This prospective study called for the placement of 59 implants to obtain a target of 90% power. To compensate for possible dropouts, the sample size was adjusted to 67 implants. To assess marginal bone level changes, periapical radiographs were taken at baseline, 1 year, and 5 years after the definitive restorations. Peri-implant soft tissue modifications were evaluated by performing a photographic sequence at 15 days, 1 year, and 5 years after implant restoration. Parameters measured were: (1) distance from the tip o f the papilla to the contact point and (2) apicocoronal crown length. Results: A one-way analysis o f variance (ANOVA rank test) was used to compare quantitative data among the three time points studied. Mean marginal bone level changes were as follows: -0,0 6 +/- 0.32 mm from baseline to 1 year, -0,2 3 +/- 0.38 mm from 1 to 5 years, and -0.2 8 +/- 0.45 mm from baseline to 5 years. In bone-level outcomes, no statistically significant differences were found between baseline and 1 year, while the mean differences between 1 and 5 years and baseline and 5 years showed statistically significant differences. In the soft tissue analysis, the distance from the tip of the papilla to the contact point showed the following values: baseline, 2.08 trim; 1 year, 1.54 mm; 5 years, 1,31 mm. No statistically significant differences were found between baseline and 1 year, whereas statistically significant differences between 1 and 5 years and baseline and 5 years were found. Apicocoronal crown length measurements showed the following values: baseline, 9.44 mm; 1 year, 9.28 mm; 5 years, 9.81 mm. No significant differences were found between times studied. Conclusion; This prospective clinical study of 67 bone-level implants restored according to the platform-switching concept reported that radiographic levels of peri-implant bone crest were statistically significant between 1 and 5 years and baseline and 5 years. For the soft tissue response, the greatest reduction in the distance from the papilla to the contact point from 1 to 5 years and baseline to 5 years was observed. No significant differences were shown in the buccal margin.
更多
查看译文
关键词
bone level,follow-up,platform switching,soft tissues
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要