谷歌浏览器插件
订阅小程序
在清言上使用

Evaluation of a fully absorbable poly-4-hydroxybutyrate/absorbable barrier composite mesh in a porcine model of ventral hernia repair

Surgical Endoscopy(2016)

引用 43|浏览11
暂无评分
摘要
Background The objective of this study was to evaluate the mechanical and histological properties of a fully absorbable poly-4-hydroxybutyrate/absorbable barrier composite mesh (Phasix™ ST) compared to partially absorbable (Ventralight™ ST), fully absorbable (Phasix™), and biologically derived (Strattice™) meshes in a porcine model of ventral hernia repair. Methods Bilateral abdominal surgical defects were created in twenty-four Yucatan pigs, repaired with intraperitoneal (Phasix™ ST, Ventralight™ ST) or retromuscular (Phasix™, Strattice™) mesh, and evaluated at 12 and 24 weeks ( n = 6 mesh/group/time point). Results Prior to implantation, Strattice™ demonstrated significantly higher ( p < 0.001) strength (636.6 ± 192.1 N) compared to Ventralight™ ST (324.3 ± 37.1 N), Phasix™ ST (206.9 ± 11.3 N), and Phasix™ (200.6 ± 25.2 N). At 12 and 24 weeks, mesh/repair strength was significantly greater than NAW ( p < 0.01 in all cases), and no significant changes in strength were observed for any meshes between 12 and 24 weeks ( p > 0.05). Phasix™ mesh/repair strength was significantly greater than Strattice™ ( p < 0.001) at 12 and 24 weeks, and Ventralight™ ST mesh/repair strength was significantly greater than Phasix™ ST mesh ( p < 0.05) at 24 weeks. At 12 and 24 weeks, Phasix™ ST and Ventralight™ ST were associated with mild inflammation and minimal–mild fibrosis/neovascularization, with no significant differences between groups. At both time points, Phasix™ was associated with minimal–mild inflammation/fibrosis and mild neovascularization. Strattice™ was associated with minimal inflammation/fibrosis, with minimal neovascularization at 12 weeks, which increased to mild by 24 weeks. Strattice™ exhibited significantly less neovascularization than Phasix™ at 12 weeks and significantly greater inflammation at 24 weeks due to remodeling. Conclusions Phasix™ ST demonstrated mechanical and histological properties comparable to partially absorbable (Ventralight™ ST) and fully resorbable (Phasix™) meshes at 12 and 24 weeks in this model. Data also suggest that fully absorbable meshes with longer-term resorption profiles may provide improved mechanical and histological properties compared to biologically derived scaffolds.
更多
查看译文
关键词
Absorbable,Biologically derived,Hernia repair,Mesh,Phasix™,Poly-4-hydroxybutyrate
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要