Orthotopic aortic transplantation using the sleeve technique reduces injury to the aorta with failure rate of only 10-20%. The time to anastomose the aorta in mice using the sleeve method was short and easy averaging 20 min, permitting studies of iso/allo grafts. The following article describes the aortic transplantation procedure used in our laboratory. The mice were anesthetized with a mixture of 1.5% volume isoflurane and 100% oxygen through a face mask. At this point, the segment of the aorta between the renal arteries and its bifurcation was separated from the vena cava, freely prepared and clampedat the proximal and distal segments with a single silk suture. Prior to the removal of the aorta, a saline solution containing heparin was injected into the inferior vena cava. Then the aorta was cut between the clamps and a saline heparin solution was used to flush the lumen. The sleeve technique with monofilament sutures was used in order to transplant the abdominal aorta in the orthotopic position.