Performance Evaluation of Four 25-Hydroxyvitamin D Assays to Measure 25-Hydroxyvitamin D2
Clinical Biochemistry(2015)
Siemens Healthcare Diagnostics Inc
Abstract
Objectives: The ability of current immunoassays to accurately measure equimolar amounts of 25(OH)D-2 and 25(OH)D-3 has been recently questioned. This study determined serum 25(OH)D-2, 25(OH)D-3 and total serum 25(OH)D concentrations in healthy vitamin D-2-supplemented subjects by isotope dilution liquid chromatography mass spectrometry (ID-LC-MS/MS); and, evaluated the ability of the Siemens, DiaSorin, Roche, and Abbott Vitamin D Total assays to monitor total serum 25(OH)D concentrations compared to an ID-LC-MS/MS method traceable to the National Institute of Standards and Technology (NIST), and that has achieved certification from the Centers for Disease Control and Prevention (CDC) Vitamin D Standardization Certification Program (VDSCP).Design and methods: Twenty (20) healthy adults, with no history of prior vitamin D supplementation were administered oral vitamin D-2 (2400 IU/day for 6 months). Serum samples (140) from baseline and monthly blood draws were tested.Results: After one month, the mean serum 25(OH)D-2 concentrations rose from 0.8 to 43.6 nmol/L, whereas 25(OH)D3 concentrations declined from 84.0 to 63.4 nmol/L; total serum 25(OH)D concentrations rose from 86.6 to 107.0 nmol/L. The overall mean bias to ID-LC-MS/MS was -7.1% for the Siemens ADVIA Centaur assay, -15.3% for the DiaSorin LIAISON assay; -8.4% for the Roche ELECSYS assay and -16.3% for the Abbott ARCHITECT assay. Correlation coefficients (r) were 0.94, 0.79, 0.74, and 0.73; the mean bias for baseline [25(OH) D-3-containing] versus six-month [25(OH)D-2- and 25(OH)D-3-containing] samples was -13.4% and -5.7%; -3.5% and 20.3%, 9.6% and -12.1%, and 0.2% and -17.8%, respectively.Conclusions: The bias results obtained for the Siemens ADVIA Centaur assay and Roche ELECSYS assay were slightly lower than those for the DiaSorin LIAISON assay and the Abbott ARCHITECT assay, but all 25(OH)D assays demonstrated acceptable performance. (C) 2015 Siemens Healthcare Diagnostics Inc. The Canadian Society of Clinical Chemists. Published by Elsevier Inc.
MoreTranslated text
Key words
Vitamin D total assay,ID-LC-MS/MS,VDSCP,25 Hydroxyvitamin D,Vitamin D,25(OH)D,25(OH)D3,25(OH)D2
PDF
View via Publisher
AI Read Science
Must-Reading Tree
Example

Generate MRT to find the research sequence of this paper
Related Papers
2009
被引用100 | 浏览
2008
被引用112 | 浏览
2004
被引用91 | 浏览
1984
被引用138 | 浏览
2010
被引用170 | 浏览
2014
被引用3590 | 浏览
1998
被引用587 | 浏览
2011
被引用14176 | 浏览
2008
被引用734 | 浏览
1986
被引用89 | 浏览
2001
被引用590 | 浏览
2012
被引用369 | 浏览
1986
被引用143 | 浏览
2012
被引用293 | 浏览
2012
被引用589 | 浏览
2012
被引用56 | 浏览
Data Disclaimer
The page data are from open Internet sources, cooperative publishers and automatic analysis results through AI technology. We do not make any commitments and guarantees for the validity, accuracy, correctness, reliability, completeness and timeliness of the page data. If you have any questions, please contact us by email: report@aminer.cn
Chat Paper
GPU is busy, summary generation fails
Rerequest