谷歌浏览器插件
订阅小程序
在清言上使用

Simple and Accurate Empirical Absolute Volume Calibration of a Multi-Sensor Fringe Projection System

Optics and lasers in engineering(2016)

引用 7|浏览7
暂无评分
摘要
This paper suggests a novel absolute empirical calibration method for a multi-sensor fringe projection system. The optical setup of the projector-camera sensor can be arbitrary. The term absolute calibration here means that the centre of the three dimensional coordinates in the resultant calibrated volume coincides with a preset centre to the three-dimensional real-world coordinate system. The use of a zero-phase fringe marking spot is proposed to increase depth calibration accuracy, where the spot centre is determined with sub-pixel accuracy. Also, a new method is proposed for transversal calibration. Depth and transversal calibration methods have been tested using both single sensor and three-sensor fringe projection systems. The standard deviation of the error produced by this system is 0.25mm. The calibrated volume produced by this method is 400mm×400mm×140mm.
更多
查看译文
关键词
Depth calibration,Transversal calibration,Empirical calibration,Absolute calibration,Multi-sensor fringe projection systems