谷歌浏览器插件
订阅小程序
在清言上使用

Setup and commissioning of the diagnostics beamline for the srf photoinjector project at rossendorf

msra(2008)

引用 23|浏览2
暂无评分
摘要
A superconducting radio frequency photo electron injector (SRF injector) has been developed by a collaboration of BESSY, DESY, FZD and MBI and is in operation since late 2007. After the initial commissioning in late 2007 with a Copper photocathode a Caesium-Telluride cathode was installed early 2008 to allow for high charge production. The longitudinal and transverse electron beam parameters are measured in a compact diagnostics beamline. This paper describes results from beam commissioning of the main diagnostic tools. Special emphasis is given on the bunch length measurement system for the 15 ps FWHM electron bunches. The system is based on the conversion of the electron pulses into radiation pulses by Cherenkov radiation. These radiation pulses are transported in a novel fullyreflective, relay imaging optical beamline to a streak camera, where the temporal properties of the pulses are measured.