谷歌浏览器插件
订阅小程序
在清言上使用

Splits of Windage Losses in Integrated Transient Rotor and Stator Thermal Analysis of a High-Speed Alternator During Multiple Discharges

ieee(2005)

引用 11|浏览3
暂无评分
摘要
For a high speed electrical alternator, the rotor outer banding and stator inner liner are typically made of high strength graphite epoxy composites due to their high strength and stiffness. Machine structural integrity at high rotating speeds degrades significantly as the composite resins lose their strength at high temperatures. The magnitude of the frictional windage losses generated in the air gaps and the splits of the windage losses between the rotor and stator become crucial to the machine design since these windage losses greatly influence the rotor outer and stator inner surface temperatures.Splits of windage losses generated by an enclosed high speed composite rotor in low air pressure environments were investigated by The University of Texas at Austin Center for Electro mechanics and described in a companion paper. The windage splits are dictated by the air temperature gradients at the rotor outer and stator inner surfaces. Unique heating, cooling, and component material properties of a typical highspeed alternator during repetitive-discharge events make its transient air-gap windage splits very much different from those of the test setup.This paper describes transient windage splits in integrated rotor and stator thermal analyses of a high-speed alternator designed for multiple discharges. The transient windage splits in the air-gap airflow were obtained through multiple iterations on windage losses, air-gap air temperatures, and rotor and stator surface temperatures.
更多
查看译文
关键词
splits of windage losses,high-speed alternator,multiple discharges
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要