谷歌浏览器插件
订阅小程序
在清言上使用

Dobutamine-atropine Stress Echocardiography and Dipyridamole Sestamibi Scintigraphy for the Detection of Coronary Artery Disease: Limitations and Concordance

Anesthesiology(1998)

引用 75|浏览3
暂无评分
摘要
OBJECTIVES We sought to compare dobutamine-atropine stress echocardiography (DASE) and dipyridamole Technetium 99-m (Tc-99m) sestamibi single photon emission computed tomography (SPECT) scintigraphy (DMIBI) for detecting coronary artery disease (CAD).BACKGROUND Both DASE and DMIBI are effective for evaluating patients for CAD, but their concordance and limitations have not been directly compared.METHODS To investigate these aims, patients underwent multistage DASE, DMIBI and coronary angiography within three months. Dobutamine-atropine stress echocardiography and stress-rest DMIBI were performed according to standard techniques and analyzed for their accuracy in predicting the extent of CAD. Segments were assigned to vascular territories according to standard models. Angiography was performed using the Judkin's technique.RESULTS The 183 patients (mean age: 60 +/- 11 years, including 50 women) consisted of 64 patients with no coronary disease and 61 with single-, 40 with two- and 18 with three-vessel coronary disease. Dobutamine-atropine stress echocardiography and DMIBI were similarly sensitive (87%, 104/119 and 80%, 95/119, respectively) for the detection of CAD, but DASE was more specific (91%, 58/64 vs. 73%, 47/64, p < 0.01). Sensitivity was similar for the detection of CAD in patients with single-vessel disease (84%, 51/61 vs. 74%, 45/61, respectively) and multivessel disease (91%, 53/58 vs. 86%, 50/58, respectively). Multiple wall motion ai,normalities and perfusion defects were similarly sensitive for multivessel disease (72%, 42/58 vs. 66%, 38/53, respectively), but, again, DASE was more specific than DMIBI (95%, 119/125 vs. 76%, 95/125, respectively, p < 0.01). Dobutamine-atropine stress echocardiography and DMIBI were moderately concordant for the detection and extent of CAD (Kappa 0.47, p < 0.0001) bur were only fairly (Kappa 0.35, p < 0.001) concordant for the type of abnormalities (normal, fixed, ischemia or mixed).CONCLUSIONS Dobutamine-atropine stress echocardiography and DMIBI were comparable tests for the detection of CAD. Both were very sensitive for the detection of CAD and moderately sensitive for the extent of disease. The only advantage of DASE was greater specificity, especially for multivessel disease. Dobutamine-atropine stress echocardiography may be advantageous in patients with lower probabilities of CAD. CT Am Coil Cardiol 2000;36: 1265-73) (C) 2000 by the American College of Cardiology.
更多
查看译文
关键词
CAD,DASE,DMIBI,LAD,LCX,MI,RCA,SPECT,Tc-99m
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要