X-ray computed tomography (CT), based on the measurement of x-ray attenuation from a multitude of view angles around the patient, is the workhorse of the radiologist. Since the introduction of CT in 1972, the importance of CT for the medical healthcare has increased dramatically. Major technical, mathematical, algorithmical and clinical improvements have taken place in the meantime over nearly four decades. Today, the most modern clinical scanners perform up to four rotations per second and thereby simultaneously acquire up to 320 slices that cover a 50 centimeter diameter field of measurement with a length of up to two meters. Complete patients can be assessed with CT in less than five seconds with an isotropic spatial resolution of down to 0.3 millimeters, with a temporal resolution as good as 70 milliseconds, and with image noise being less than 5% of the image contrast. Further on, dual energy CT allows assessing spectroscopic properties of the object, such as the exact quantification of iodine within muscle tissue or as the chemical composition of renal stone prior to treatment, for example. The spectrum of clinical CT applications is sophisticated and manifold. Typical applications are standard scans, whole body scans for trauma patients, cardiac CT, dual energy CT, dynamic CT, CT angiography, cardiac or coronary CT angiography, bone densitometry, lung screening, virtual colonoscopy, and many more.
Besides clinical computed tomography, several other medical CT modalities are in use, today. Interventional studies, for example, are often carried out under C-arm CT guidance, where a flat detector and a small x-ray source rotate around the patient. Oral and maxillofacial surgery, as well as the planning of dental implants, often relies on the so-called digital volume tomography (DVT), which is a dedicated flat detector CT system for the patient head. Radiation therapy even uses two CT modalities for image guidance: a clinical CT scan is used for planning, while the treatment unit itself is equipped with dedicated flat detector CT systems used for patient positioning and treatment verification. In the preclinical domain dedicated small animal CT systems are in use. They allow supporting longitudinal pharmaceutical studies that may aim at monitoring tumor response or the influence of other medication. Often, CT is used in multi-modality scenarios to add prior information to other modalities. Among those scenarios combinations of PET with CT or SPECT with CT are the most prominent ones in medical care.
The division “x-ray imaging and computed tomography” of the DKFZ aims at improving x-ray and CT imaging in all aspects, with a special focus on cancer detection and tumor characterization. While calibration, preprocessing and dose reduction applies to both, radiographic and tomographic imaging, sophisticated image reconstruction and artifact reduction techniques is our focus in CT research. This includes the development of new methods to perform real-time imaging simulta-neously with the radiation treatment, potentially combining the information obtained by the kV imager with the portal images obtained from the MV treatment beam, the development of new registration and reconstruction algorithms to compensate for patient motion, as well as the development of new multi-spectral imaging techniques to improve tumor diagnosis and to allow for quantitative tissue decomposition into the dominating chemical components. Further, some of our projects aim at translating and adapting methods, originally developed for CT, to other imaging modalities, such as MRI and PET.
Besides clinical computed tomography, several other medical CT modalities are in use, today. Interventional studies, for example, are often carried out under C-arm CT guidance, where a flat detector and a small x-ray source rotate around the patient. Oral and maxillofacial surgery, as well as the planning of dental implants, often relies on the so-called digital volume tomography (DVT), which is a dedicated flat detector CT system for the patient head. Radiation therapy even uses two CT modalities for image guidance: a clinical CT scan is used for planning, while the treatment unit itself is equipped with dedicated flat detector CT systems used for patient positioning and treatment verification. In the preclinical domain dedicated small animal CT systems are in use. They allow supporting longitudinal pharmaceutical studies that may aim at monitoring tumor response or the influence of other medication. Often, CT is used in multi-modality scenarios to add prior information to other modalities. Among those scenarios combinations of PET with CT or SPECT with CT are the most prominent ones in medical care.
The division “x-ray imaging and computed tomography” of the DKFZ aims at improving x-ray and CT imaging in all aspects, with a special focus on cancer detection and tumor characterization. While calibration, preprocessing and dose reduction applies to both, radiographic and tomographic imaging, sophisticated image reconstruction and artifact reduction techniques is our focus in CT research. This includes the development of new methods to perform real-time imaging simulta-neously with the radiation treatment, potentially combining the information obtained by the kV imager with the portal images obtained from the MV treatment beam, the development of new registration and reconstruction algorithms to compensate for patient motion, as well as the development of new multi-spectral imaging techniques to improve tumor diagnosis and to allow for quantitative tissue decomposition into the dominating chemical components. Further, some of our projects aim at translating and adapting methods, originally developed for CT, to other imaging modalities, such as MRI and PET.
Research Interests
Papers共 406 篇Author StatisticsCo-AuthorSimilar Experts
By YearBy Citation主题筛选期刊级别筛选合作者筛选合作机构筛选
时间
引用量
主题
期刊级别
合作者
合作机构
MEDICAL IMAGING 2024 PHYSICS OF MEDICAL IMAGING, PT 1 (2024)
MEDICAL IMAGING 2024 PHYSICS OF MEDICAL IMAGING, PT 1 (2024)
Quantification of Biophysical Parameters in Medical Imagingpp.537-545, (2024)
MEDICAL PHYSICSno. 3 (2024): 1597-1616
MEDICAL PHYSICSno. 7 (2024): 4793-4810
MEDICAL PHYSICS (2024)
Quantification of Biophysical Parameters in Medical Imagingpp.365-377, (2024)
MEDICAL PHYSICS (2024)
S. Sawall, E. Baader, J. Wolf,J. Maier,H. -P. Schlemmer, S. O. Schoenberg,I. Sechopoulos,M. Kachelriess
Physica medica (2024): 103378-103378
Load More
Author Statistics
#Papers: 409
#Citation: 9320
H-Index: 47
G-Index: 89
Sociability: 7
Diversity: 3
Activity: 40
Co-Author
Co-Institution
D-Core
- 合作者
- 学生
- 导师
Data Disclaimer
The page data are from open Internet sources, cooperative publishers and automatic analysis results through AI technology. We do not make any commitments and guarantees for the validity, accuracy, correctness, reliability, completeness and timeliness of the page data. If you have any questions, please contact us by email: report@aminer.cn