Development of a dual immunochromatographic test strip to detect E2 and Erns antibodies against classical swine fever

FRONTIERS IN MICROBIOLOGY(2024)

引用 0|浏览6
暂无评分
摘要
Background: It is essential to consider a practical antibody test to successfully implement marker vaccines and validate vaccination efficacy against classical swine fever virus (CSFV). The test should include a serological antibody assay, combined with a tool for differentiating infected from vaccinated animals (DIVA). The immunochromatographic test strip (ICS) has been exclusively designed for detecting CSFV E2 antibodies while lacking in detecting E-rns antibodies, which can be employed and satisfy DIVA strategy. This study developed a novel ICS for detecting CSFV E2/E-rns dual-antibody. The effectiveness of ICS in evaluating the DIVA capability of two novel chimeric pestivirus vaccine candidates was assessed. Methods: Recombinant E2 or E-rns protein was transiently expressed in the plant benthamiana using Agrobacterium tumefaciens. ICS was subsequently assembled, and goat anti-rabbit IgG and recombinant CSFV E2 or E-rns protein were plated onto the nitrocellulose membrane as control and test lines, respectively. The sensitivity and specificity of ICS were evaluated using sera with different neutralizing antibody titers or positive for antibodies against CSFV and other pestiviruses. The coincidence rates for detecting E2 and E-rns antibodies between ICS and commercial enzyme-linked immunosorbent assay (ELISA) kits were also computed. ICS performance for DIVA capability was evaluated using sera from pigs vaccinated with conventional vaccine or chimeric vaccine candidates. Results: E2 and E-rns proteins were successfully expressed in N. benthamiana-produced recombinant proteins. ICS demonstrated high sensitivity in identifying CSFV E2 and E-rns antibodies, even at the low neutralizing antibody titers. No cross-reactivity with antibodies from other pestiviruses was confirmed using ICS. There were high agreement rates of 93.0 and 96.5% between ICS and two commercial ELISA kits for E2 antibody testing. ICS also achieved strong coincidence rates of 92.9 and 89.3% with two ELISA kits for E-rns antibody detection. ICS confirmed the absence of CSFV E-rns-specific antibodies in sera from pigs vaccinated with chimeric vaccine candidates. Conclusion: E2 and E-rns proteins derived from the plant showed great potential and can be used to engineer a CSFV E2/E-rns dual-antibody ICS. The ICS was also highly sensitive and specific for detecting CSFV E2 and E-rns antibodies. Significantly, ICS can fulfill the DIVA concept by incorporating chimeric vaccine candidates.
更多
查看译文
关键词
classical swine fever,immunochromatographic test strip,E2,E-rns,antibody detection
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要