Case report: Skin protective barrier cream interference in benzethonium chloride method for urine protein measurement in a 6-month-old girl.

Ömer Özcan, Joanna Ae van Wijk,Annet M Bosch, Wendy Pj den Elzen, Annemieke C Heijboer,Johan C Fischer

Annals of clinical biochemistry(2023)

引用 0|浏览31
暂无评分
摘要
This case report describes the positive interference of the commonly used skin protective barrier cream used together with urine collection bags on the benzethonium chloride method for urine protein measurements in a 6-month-old female baby, leading to falsely elevated results. The interference was identified by both artificially mixing urine samples with this cream and comparing the results obtained using the benzethonium chloride method with those obtained using the pyrogallol red method.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要