Closed Reduction of a Dislocated Constrained Total Hip Arthroplasty with 2-Year Follow-up: A Case Report

Arthroplasty today(2023)

引用 0|浏览1
暂无评分
摘要
In the setting of chronic instability following total hip arthroplasty, implantation of a constrained acetabular liner may be warranted. We report on a patient who sustained a posterior prosthetic hip dislocation out of the constrained acetabular liner component (Stryker Trident [Kalamazoo, MI]), which had been previously replaced 2 months prior, and underwent a successful closed reduction in the emergency department. At 2-year follow-up, the patient’s prosthetic hip has remained stable with no reported issues. To our knowledge, this is the first reported closed reduction of a revised constrained total hip arthroplasty with this implant system, size, and length of follow-up.
更多
查看译文
关键词
Closed reduction,Constrained liner,Case report,Revision,Total hip arthroplasty