Two proposals to simplify resistive sensor readout based on Resistance-to-Time-to-Digital conversion

MEASUREMENT(2023)

引用 0|浏览3
暂无评分
摘要
Direct Interface Circuits (DICs) are simple circuits used in readouts for all types of sensors. For resistive sensors, all DICs perform a resistance-to-time-to-digital conversion using just the sensor, some calibration resistors, one or two capacitors, and a Digital Processor. These circuits require a variable number of charging and discharging cycles of a capacitor to estimate the sensor resistance, Rx, increasing both acquisition time and power con-sumption. This paper presents two resistive DICs capable of estimating Rx by means of a single charging -discharging process, simplifying the readout process. Furthermore, this is achieved without increasing hard-ware requirements. Only two time measurements are used to obtain Rx. Despite the simplicity of the new circuits, the experimental results show that relative errors of estimating Rx can be below 0.8 %, and this in a wide range of resistances of over 40 dB. Moreover, acquisition time and energy consumption can be reduced by up to 75 %.
更多
查看译文
关键词
Direct interface circuits,Resistance-to-time-to-digital conversion,Resistive sensor,Time-based measurement