ABSOLUTE INTENSITIES OF HELIUM LINES AND SPACE RESOLVED ELECTRON DENSITIES AND ENERGIES IN DISCHARGE WITH A HOLLOW CATHODE IN HE:H2O GAS MIXTURE

Sergey N. Andreev,Anton Bernatskiy, Ivan Draganov,Igor Kochetov, Vladimir N. Ochkin

High Temperature Material Processes: An International Quarterly of High-Technology Plasma Processes(2023)

引用 0|浏览2
暂无评分
摘要
In a discharge with a hollow cathode the electron energy distribution functions (EEDFs), electron concentration, and absolute intensities of pure helium and helium mixtures with water vapor at pres-sures of 2-3 mbar were measured. It was shown that under the experiment conditions, the EEDFs were significantly different from the Maxwellian function since the amount of high-energy electrons in the energy range of 7-24 eV was much larger. As the concentration of water molecules in plasma increased, the amount of high-energy electrons decreased. The absolute intensities of a number of he-lium lines were calculated in coronal model approximation. It was determined that the lines reasonably agreed with the experimental measurements of the absolute intensities.
更多
查看译文
关键词
Langmuir probe, electron energy distribution, hollow cathode, nonlocal kinetics
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要