谷歌浏览器插件
订阅小程序
在清言上使用

Mp38-10 tensile strength of penile tunica albuginea in a human model

Journal of Urology(2022)

引用 0|浏览2
暂无评分
摘要
You have accessJournal of UrologyCME1 May 2022MP38-10 TENSILE STRENGTH OF PENILE TUNICA ALBUGINEA IN A HUMAN MODEL Alexander M. Kandabarow, Eric Chuang, Kevin McKenna, Brian Le, Kevin McVary, and Alberto Colombo Alexander M. KandabarowAlexander M. Kandabarow More articles by this author , Eric ChuangEric Chuang More articles by this author , Kevin McKennaKevin McKenna More articles by this author , Brian LeBrian Le More articles by this author , Kevin McVaryKevin McVary More articles by this author , and Alberto ColomboAlberto Colombo More articles by this author View All Author Informationhttps://doi.org/10.1097/JU.0000000000002592.10AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookLinked InTwitterEmail Abstract INTRODUCTION AND OBJECTIVE: There is a paucity of data surrounding the biomechanical properties of the tunica albuginea (TA) in current literature. This is surprising as the TA is the main load-bearing tissue during erection and its biomechanical properties are critical to understanding the penile physiology and the expansion of corpora cavernosa. We previously quantified the Young’s modulus and ultimate tensile strength (UTS) of TA in primates and we now compare these values with human TA tissue. METHODS: We procured tissue from patients undergoing penectomy. Strips of TA were dissected in both longitudinal and circumferential orientations. We measured the thickness, the width and the length of every sample in three different locations and took the average of each. We generated stress-strain curves via mechanical extensometry using an Instron Machine. From this curve the Young’s modulus (a measure of stiffness) and ultimate tensile strength were calculated. Comparisons between human and baboon values were performed with a t-test. RESULTS: Six samples from 3 penes produced a mean Young’s modulus of 8.1 MPa (SD 1.7) longitudinally (n=3) and 10.3 MPa (SD 3.1) circumferentially (n=4). The mean ultimate tensile strength was 1.8 MPa (SD 0.6) longitudinally and 1.7 MPa (SD 0.1 MPa) circumferentially. These values show that human tunica albuginea has a stiffness between cartilage and cancellous bone. In comparison with baboons (Papio anubis), human samples had a lower Young’s modulus longitudinally (8.1 vs 34.0, p <0.01) but not circumferentially (10.3 vs 11.7, p=0.32). Additionally, the human samples had a lower maximum stress longitudinally (1.8 vs 4.3, p=0.01) but not circumferentially (1.7 vs 2.0, p=0.29). These data show that baboon TA is stiffer and stronger longitudinally than human TA. CONCLUSIONS: These measures of fresh human TA show some variation between human and primate models and support the need for fresh human tissue measurements to characterize the mechanical properties of the penis. These data will be critical in developing in silico models that can be used to investigate mechanical disease states of the penis and predict tissue/prosthesis interactions. Source of Funding: Loyola University Chicago internal grant © 2022 by American Urological Association Education and Research, Inc.FiguresReferencesRelatedDetails Volume 207Issue Supplement 5May 2022Page: e622 Advertisement Copyright & Permissions© 2022 by American Urological Association Education and Research, Inc.MetricsAuthor Information Alexander M. Kandabarow More articles by this author Eric Chuang More articles by this author Kevin McKenna More articles by this author Brian Le More articles by this author Kevin McVary More articles by this author Alberto Colombo More articles by this author Expand All Advertisement PDF DownloadLoading ...
更多
查看译文
关键词
Urogynecology
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要